82Z30000.book 22 ページ 2010年6月25日 金曜日 午後5時50分
GENERATOR/CHARGING SYSTEM
CIRCUIT PROTECTOR INSPECTION
(EXCEPT RHH TYPE)
Remove the circuit protector (1) (page 10-3).
Check continuity between the terminals. There should
be continuity in the ON position (button in) and no
continuity in the OFF position (button out). Replace the
circuit protector if the correct continuity is not obtained.
Switch position
ON
OFF
REGULATOR/RECTIFIER INSPECTION
(CXS TYPE ONLY)
Remove the regulator/rectifier (page 10-3).
Check for continuity between the terminals according to
the table below.
CONTINUITY:
(–)
probe
• Some meters show current flow from negative (–) to
positive (+), others show flow from positive (+) to
negative (–). The polarity of the meter does not
matter when testing diodes. As long as the meter
shows current flowing one way and not the other the
diode is good.
FUEL CUT/CHARGE COIL INSPECTION
Remove the harness clip base bolts (page 8-5).
Disconnect the fuel cut/charge coil wire connector
.
Measure the resistance between the fuel cut/charge coil
wire connector
terminal and the engine ground.
Resistance:
7-22
Continuity
Yes
No
(+) probe
1
2
3
1
NO
NO
2
NO
YES
3
NO
NO
fuel cut/charge coil side (White)
0.3 – 0.5 Ω
(1)