82Z30000.book 15 ページ 2010年6月25日 金曜日 午後5時50分
MAIN WINDING INSPECTION
VOLTAGE INSPECTION
Remove the two screws (1) and generator end cover
(2).
Start the engine and measure the AC voltage between
the terminals according to the table below.
RH, KH, MH type
RHH, RGH type
UH type
SH, SKH type
LDH, LTH type
Main winding terminal
(Brown) and
(White)
Main winding terminal
(Brown) and
(White)
Main winding terminal
(Brown) and
(White)
Main winding terminal
(Brown) and
(White)
Main winding terminal
(Red) and
(White)
(Gray) and
(Blue)
GENERATOR/CHARGING SYSTEM
Voltage
(VAC)
210 - 230
Voltage
(VAC)
220 - 240
Voltage
(VAC)
230 - 250
Voltage
(VAC)
210 - 230
Voltage
(VAC)
110 - 130
110 - 130
(2)
(1)
7-15