The Setup Prefs Submenu; Setup Prefs Help - Turning The Help Screen On And Off; Setup Prefs Freeze - Holding Active Outputs During; Setup Prefs Times - Setting Default In And Outfade Times - Jands Event 4 User Manual

Hide thumbs Also See for Event 4:
Table of Contents

Advertisement

17.6 The Setup Prefs Submenu

Press Setup and open the Prefs submenu to set various console preferences as
follows. Move the cursor to the more field to reveal the second screen.
17.6.1

Setup Prefs Help - Turning the Help Screen On and Off

Help
17.6.2
Setup Prefs Freeze – Holding Active Outputs During Page
Changes
Freeze
17.6.3

Setup Prefs Times - Setting Default In and Outfade Times

Before recording Memories it can be helpful to set default fade times to avoid the
necessity of setting times for each Memory.
Times
Note:
settings for any Memory at a later time.
17.6.4
Setup Prefs Increment - Changing the Increment between
Memories
The Event 4 defaults to advancing the Memory number by 1 each time a memory is
recorded. This increment can be changed to suit different recording styles.
Increment
TIP:
Memory menu would advance to M20. The Memory number can still be set to any
intermediate value by typing the required number from the keypad.
17.6.5
Setup Prefs PrevInt – Customising the Next function
The Programmer Next button is used to quickly step through a number of Fixtures,
highlighting one at a time. When Next is pressed any selected Fixtures are deselected
and their intensity is set to the Previous Intensity level (default - 15%). Then the next
25/11/02
Set
Help Freeze
Prefs Off
On
Set
PrevInt NextInt
Prefs
15
Sets the left hand Assign master LCD to display context sensitive help
screens. This option is only available on Event 416 consoles.
If Freeze is on, any Assign faders that are above zero % when the Page
was changed will continue to control the old Page Memory until the
faders are returned to zero at which time they will join the new Page. Any
'frozen' item's label will flash between its label and number to make it
easy to identify.
Sets the default fade time for any memories. The time can be set from
0.1S to 9M 59.9S
Default times will only be added to new Memories. It is possible to edit the
Sets the default increment between memories.
Can be set from 0.01 to 10
If the increment was set to 10 and the first Memory recorded was M10 the
Times Increment
0:02.0
1
PTime
100
0:01.0
Draft
Software Version 5.0
More