The Memory Menu - Jands Event 4 User Manual

Hide thumbs Also See for Event 4:
Table of Contents

Advertisement

JANDS – Event 4 Version 5 Users Manual
Time
10.2.1

The Memory menu

Press the Mem button to open the Memory menu. There are 2 levels to this menu.
When the cursor is moved to the more field additional parameter fields are displayed.
Mem
Label
Infade
NOTE:
the infade time is changed the outfade time field changes to the same value. To set a
different outfade time simply move the cursor to the outfade field and change it.
Outfade This field sets the time the Memory will take to fade from 100% to 0%,
Next
TIP:
the + (On) or – (Off) button to edit the field, use the left arrow button to move the
cursor over the M, then press the + (On) button to change the M to a C, (this can also
be achieved by pressing the Flash button marked C. In the Chase menu press flash
button M to change to a memory number.
Delay
Note:
Mask
Page 36
Press the button above the field and press the IFCB buttons to change the
Mask settings.
Sets any or all of Intensity, Focus, Colour and Beam to use timing during
playback. Any letter (IFCB) shown indicates that the parameter will fade
in and out using times set in the Memory menu. Eg. if the display shows
IF--, then when triggered, the Intensity and Position parameters will
follow the fade time, while the colour and beam will snap to the new
value.
Press the button above the field and press the IFCB buttons to change the
Time settings.
Mem
M—10 Infade Outfade Next
M 10.00 ---- 0:02.0 0:02.0
Mem
Delay
Mask Time Time Code
M 10.00 0:00.0 ---- IF-- --:--:--:--
This field sets the Memory number to be recorded or adjusted.
Type a label of up to eight characters using an external keyboard or the
Flash buttons. (see below for a more detailed explanation of labelling)
This field sets the time the Memory will take to fade from 0% to 100%,
ie. if set to 0:10.5, it will take 10.5 seconds to fade to full output.
By default the Outfade field automatically tracks the infade time – that is, if
ie. if set to 0:02, it will take 2 seconds to fade out.
This field sets which item follows the Memory or Chase when used in a
Stack. See the section on Stacks for information on usage.
To change the Next field setting from a Memory number to a Chase, press
This field is used to set automatic follow on and sets the time between the
Infade completion of this Memory and the start of the Infade of the
Memory or Chase set in the NEXT field. See the section on Stacks for
information on usage
A delay setting of 0:00.0 means that delay is Off.
Sets the parameters to be masked during playback. See the following
section for information on usage.
Revision 5.0.0.5
M 11 more
25/11/02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents