Electric boiler, indoor module
Hide thumbs Also See for VVM 225:
Table of Contents

Advertisement

factor system
heating
Setting range: 0.0 - 6.0
Factory setting heating: 1.0
cooling (accessory required)
Setting range: 0.0 - 6.0
Factory setting cooling: 1.0
Room sensors to control the room temperature can be activated here.
Here you can set a factor (a numerical value) that determines how much an over
or sub normal temperature (the difference between the desired and actual room
temperature) in the room is to affect the supply temperature to the climate
system. A higher value gives a greater and faster change of the heating curve's
set offset.
If several climate systems are installed the above settings can be made for the
relevant systems.
COOLING SETTINGS (ACCESSORY REQUIRED)
Menu
1.9.5
NIBE VVM 225
Caution
A slow heating system such as underfloor heating may not be suitable
for control using the installation's room sensors.
NOTE
Too high a set value for "factor system" can (depending on your climate
system) produce an unstable room temperature.
room sensor settings 1.9.4
control room sensor syst
heating factor system 1
cooling factor system 1
control room sensor syst 2
control room sensor syst 3
control room sensor syst 4
Chapter 3 | VVM 225 – at your service
39