Nibe VVM 225 User Manual page 73

Electric boiler, indoor module
Hide thumbs Also See for VVM 225:
Table of Contents

Advertisement

current value
Setting range: -3000 – 3000
start compressor
Setting range: -1000 – -30
Default value: -60
start diff additional heat
Setting range: 100 – 1000
Factory setting: 700
diff. between additional steps
Setting range: 0 – 1000
Factory setting: 100
Degree minutes are a measurement of the current heating requirement in the
house and determine when the compressor respectively additional heat will
start/stop.
FACTORY SETTING USER
Menu
4.9.4
All settings that are available to the user
(including advanced menus) can be reset
to default values here.
SCHEDULE BLOCKING
Menu
4.9.5
NIBE VVM 225
Caution
Higher value on "start compressor" gives more compressor starts,
which increase wear on the compressor. Too low value can give uneven
indoor temperatures.
Caution
After factory setting, personal
settings such as heating
curves must be reset.
degree minute setting4.9.3
current value
start compressor
start diff additional heat
diff. between additional steps
Do you want to reset all user settings to
factory settings?
no
Chapter 3 | VVM 225 – at your service
DM
DM
DM
DM
factory setting user 4.9.4
yes
73