heating
Setting range: 5-70 °C
Default value: 20 °C
cooling (accessory required)
Factory setting: 18 °C
In menu 1.9.3 you select heating or cooling, in the next menu (min. supply
temp.heating/cooling) set the minimum temperature on the supply temperature
to the climate system. This means that VVM 225 never calculates a temperature
lower than that set here.
If there is more than one climate system the setting can be made separately for
each system.
ROOM SENSOR SETTINGS
Menu
1.9.4
38
Chapter 3 | VVM 225 – at your service
TIP
The value can be increased if you have, for example, a cellar that you
always want to heat, even in summer.
You may also need to increase the value in "stop heating" menu 4.9.2
"auto mode setting".
min. flow line temp. heating 1.9.3.1
climate system 1
climate system 2
climate system 3
climate system 4
min. flow line temp. cooling1.9.3.2
climate system 1
climate system 2
climate system 3
climate system 4
20
°C
20
°C
20
°C
20
°C
18
°C
18
°C
18
°C
18
°C