5. Loosen screws and adjust the cell so that the "red" sensor is reflecting off the center of the bar and
tighten the cell down .
6. Turn the gain adjustment CCW to the
minimum position .
8. Remove the material from the v-channel and close the main access cover.
9. Press the STOP key on the remote control station to clear the Main Access Cover Open alarm.
SERVICE MANUAL – QL Servo S3-T
7. From the minimum position slowly turn the
gain adjustment CW until the sensor detects
the bar. Once the sensor detects the bar
continue to turn the gain CW another ½ turn .