LNS QUICK LOAD SERVO S3 T BARFEED Service Manual page 71

Table of Contents

Advertisement

Part feed out rate (may not be visible)
APPLICATION SETUP
Part feed out with/without turret
Part feed out with turret
This parameter determines whether the lathe controls the part feeding. In this case, a special loop must be provided in its
programme.
Additional parameter (may be not visible):
a) The turret is parked in position:
the turret travels to where the material will arrive and waits for the bar feeder to push the material to this point.
b) The turret is moving to position:
The turret comes to the bar stock end; the bar feed starts pushing against the turret. Then, the turret moves to the
desired feeding length, the bar feed still maintaining the bar stock pressure against the turret.
Feeding without turret
The bar feeder feeds the part. When the collet opens, the pusher pushes the bar according to the value entered in the "total
part feeding length" parameter. The bar feeder is not able to drive the feeding cycle if the manufacturing process requires
several collet openings.
Receipt of the turret with "M" function (may not be visible)
This parameter is used to deactivate the M function receipt of the turret if this function is not used in the lathe interface. In this
case, a timer can be used to give acknowledgement.
SERVICE MANUAL – QL Servo S3-T
This parameter is used to adapt the feed rate to the weight of the
bar, for example when feeding out aluminum bars.
SETTINGS