Atto Fibrebridge Diagnostic Service Commands - ATTO Technology FibreBridge 2100R Software Manual

Atto technology fibrebridge 2100r bridges: software guide
Hide thumbs Also See for FibreBridge 2100R:
Table of Contents

Advertisement

ATTO Technology, Inc.
ScsiPortReset (Immediate)
Syntax: ScsiPortReset [PortNumber]
Returns:
Resets the specified SCSI bus. There is no get version of this command.
Temperature
Syntax: get Temperature
Returns:
(terse)
(verbose)
Reports the temperature of the unit, in C.
MaxEnclTempAlrm
Syntax: set MaxEnclTempAlrm [5 – 40]
Returns:
(terse)
(verbose)
This option sets/displays the maximum enclosure temperature alarm of the unit in degrees
Celsius. Valid entries are between 5 and 40 degrees and above the current minimum enclosure
temperature alarm.
MinEnclTempAlrm
Syntax: set MinEnclTempAlrm [5 – 40]
Returns:
(terse)
(verbose)
This option sets/displays the minimum enclosure temperature alarm of the unit in degrees
Celsius. Valid entries are between 5 and 40 degrees and below the current maximum enclosure
temperature alarm.

ATTO FibreBridge Diagnostic Service Commands

The ATTO FibreBridge Diagnostic commands are intended to aid in validating ATTO FibreBridge
operation and diagnosing / isolating ATTO FibreBridge faults.
ErrorLog for ATTO FibreBridge 2100R
Syntax: set ErrorLog clear
Returns:
The last error code saved was xx
Where xxx is : [ 960 |Static Memory | Synchronous DRAM | ISP2100 |
and Specific error text is one line of descriptive error text.
Resetting Port Number n
xx C
Temperature = xx C
get MaxEnclTempAlrm
xx C
MaxEnclTempAlrm = xx C
get MinEnclTempAlrm
xx C
MinEnclTempAlrm = xx C
get ErrorLog
[ Error Logs Cleared |
A xxx type error was detected since last error log clearing
Specific error text ]
Symbios 876 A | Symbios 876 B | FibreChannel | Software]
ATTO Technology, Inc.
ATTO FibreBridge Software Manual
14
-
-

Advertisement

Table of Contents
loading

Table of Contents