INSTALLATION

TO REMOVE EXISTING TOILET
Turn off water supply. Flush the toilet and sponge out the
remaining water from the tank and bowl. Disconnect the
supply valve, and remove the old tank and bowl.
Remove the old gasket from the floor and closet flange
with a putty knife. Remove the old T-bolts and discard.
NOTICE: If a new toilet is not installed immediately,
temporarily stuff a rag in the closet flange.
Install new 5/16" diameter T-bolts.
TO INSTALL NEW SUPPLY SHUT-OFF
VALVE
Install a toilet supply shut-off valve so it is 9" above
floorline and 4-1/2" to the left of the centerline of the closet
flange.
The centerline of the supply shut-off outlet should extend
4" from the finished wall. Install the supply shut-off valve
with the outlet vertical.
Kohler Co., Kohler, WI
T-Bolts
9"
12"
3
Closet Flange
Fig. #2
Closet Flange
Fig. #3
Supply Shut-Off
Valve
4-1/2"
Fig. #4
CA
114107-2-
(B)