EdilKamin IDROSALLY Installation, Use And Maintenance Manual page 55

Pellet boiler-stove
Hide thumbs Also See for IDROSALLY:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 32
SEAS ONAL MAINTE NANCE
(implemented by the DEALER ) Consists in:
• Clean the boiler-stove internally and externally
• Carefully clean the heat exchange tubes
• Carefully clean and remove dirt from the combustion chamber
and the relative compartment
• Clean fans, verify mechanical and clamp loosening
• Clean smoke channel (replace seals on smoke exhaust pipe)
• Clean smoke duct
• Check the expansion tank
• Check and clean the circulator
• Clean smoke extraction fan compartment.
• Clean smoke check thermocouple.
• Empty the pellet hopper and clean the base with the vacuum
cleaner.
• Clean, inspect and scrape any residue from the ignition resistan-
ce compartment and if necessary, replace it
• Visually inspect the electrical wires, connections and power cable
• Check play of the screw-gear motor group
• Clean the pellet hopper and check loosening of the feed screw -
gear motor assembly
• Replace the door seal
• Functionality test: load the feed screw, ignite, let it run for 10
minutes and shutdown
If the boiler-stove is used very frequently, it is advisable to
clean the smoke channel and the fume duct every 3 months.
ATTENTION !!!
After implementing a normal cleaning procedure, INCORRE
CT coupling of the upper (A) ( gura E) and lower (B) ( gura
E) combustion chambers can compromise the boiler-stove's
performance.
Before igniting the boiler-stove, make sure the combustion
chambers are correctly paired as indicated in ( g. F) without
ash or unburnt material present on the support perimeter.
We remind you that using the stove without cleaning the mel-
ting pot, may cause a sudden ignition gas inside the combu-
stion chamber with the consequent breaking of the glass
CLEANING THE SMOKE CHANNEL
• When the stove is cold and in stand-by, shake strongly the cle-
aning bar (see previous page); remove the bottom ceramic tile (3
g.C) and the metal cover (4 g.C).
• Remove the sheet metal (5 – g D)and the sheet panel inspec-
tion (6 – g.D), with its seal gasket (7 g.D), xed by nuts. Clean
the gasket and vacuum into the pipe
The thermo stove comes with a spare silicone gasket.
The quantity of residue which forms depends on the type of fuel
and the type of system.
If cleaning is not carried out, the boiler-stove may not function
properly.
Note: after the operation, make sure that the smoke duct
inspection closure is correctly repositioned.
MAINTENANCE
g. E
g. F
g. C
6
g. D
- 55
-
B
A
3
4
5
7
8

Advertisement

Table of Contents
loading

Table of Contents