Filling the cochlea.
The rst time you use the product, or should the tank be com-
pletely emptied of pellets, to ll the coclea press both keys "+"
and "–" on the remote control at the same time, holding for a
few seconds. As you release the keys, the display should show
the wording "LOAD".
This should be carried out before ignition if the boiler-stove has
stopped due to having run out of pellets, at the end of operation
to empty the combustion pot before turning.
It is quite normal for some pellets to remain, that the cochlea
cannot suction.
Automatic igniting.
With the boiler-stove on stand-by, press and hold the key
, on the remote control for 2 seconds. This will start-up the
ignition procedure, showing the wording "START".
At the same time, a countdown in seconds begins (from 1020
to 0). Ignition is not at a preset time, however: its duration is
automatically shortened if the board reports that certain tests
have been passed. The ame appears after about 5 minutes.
Manual igniting.
Temperatures of below 3°C will not allow the electrical resi-
stance to heat suf ciently. In this case, or should the
resistance be temporarily out of action, Diavolina
starters can be used.
Insert a piece of lit Diavolina into the combustion chamber,
close the door and press
OUTPUT TEMPERATURE ADJUSTMENT:
The SET output temperature can be altered by pressing the
keys +/-.
ENVIRONMENT TEMPERATURE ADJUSTMENT:
By activating the COMFORT CLIMA (CAT) function with
the +/- keys, the remote control device can be used as a mobile
thermostat/chronothermostat: place it in the home in a position
where the set temperature is desired, select COMFORT CLI-
MA with the menu key; the display will show the environmen-
tal temperature (AIR) and the desired environmental tempera-
ture (SET); adjust the desired temperature with the +/- keys and
the remote control dev¬ice will automatically send the request
to the stove.
Turning off
With the boiler-stove running, press and hold the key
the remote control for 2 seconds. The turn-off procedure will
begin, showing a countdown on the display from 9 to 0 (for a
total of 10 minutes).
The turn-off phase involves:
• Interruption of pellet supply
• Smoke expulsion motor
• Circulator
Unless otherwise set, managed by the CAT.
Never pull the plug out whilst the device is still in the process
of turning off.
N.B.: the circulator will continue turning for 5 - 10 minutes
after switching off.
INSTRUCTIONS FOR USE
®
type re-
the remote control.
OPERATIONS THAT CAN ONLY BE CARRIED OUT BY
REMOTE CONTROL
Clock regulation
Press and hold the key "M" for 2 seconds to access the "Clock"
menu. This allows you to set the internal electronic board
clock. By then pressing the key "M", the following data appe-
ars in sequence and can be regulated:
day, month, year, hour, minutes, day of the week.
The wording "SAVE??" will appear for con rmation with "M".
This will allow you to check that the operations performed are
correct, prior to completion (the wording "SAVE" will then be
shown on the display).
Operations for switching on, switching off and changing
the SET temperature can be carried out by means of the red
emergen¬cy button placed on the back of the boiler-stove (see
page 52).
Weekly timer
Press and hold the "M" key on the remote control for 2 secon-
ds. This turns on the clock regulation and by pressing the '+'
key, the weekly timer function is accessed, with the display
showing the description "PROGRAMM ON/OFF".
This function allows you to select the type of programming,
which allows a maximum of three ignitions to be set.
As you con rm the display with the key "M", one of the fol-
lowing options will appear:
NO PROG. (no programme set)
DAILY PROGRAM (single programme for every day of the
week)
WEEKLY PROGRAM. (speci c programme for each day
individually)
Use the "+" and "–" keys to switch between programmes.
Con rming by pressing the "M" key "DAILY PROGRAM."
and pressing the "+" key, the choice of the number of program-
mes (ignition/extinguishing) per day can be made.
Use the "DAILY PROGRAM" to set identical programme/s for
every day of the week.
By then pressing the "+" key, the following can be seen:
- Prog. no.
- 1st prog. (one turn on and one turn off per day), 2nd prog.
(identical), 3rd prog. (identical)
Use the "–" key to show in reverse order.
If the 1st programme is selected, the turn on time is shown.
The display shows: 1 "ON" at 10 Use the "+" and "–" key to
change the hour. Con rm with the "M" key (All 1 On/Hour
10).
The display shows: 1 "ON" at 30 Use the "+" and "–" key to
change the minutes. Con rm with the "M" key (1 Off min).
The same applies for the turn-off time to be set and for subse-
quent turning on and off.
rom
Con rm by pressing "M" and the wording "SAVE??" will
appear on the display.y.
When con rming "WEEKLY PROGRAM", you will need to
choose the day to which the programming is to apply:
7 Sat; Progr.1; 1 Mon ; 2 Tues; 3 Wed; 4 Thurs; 5 Fri; 6 Sa;
Once the day is set, use the keys "+" and "+" and con rm by
pushing the "M" key to choose 1 to 3 ignitions, to programme
in the same way as for the "DAILY PROGRAM", choosing
whether or not to enable a programme for each day of the
week, and if so choose the number of interventions and at what
times.
Should you make an error during programming, you can leave
the programme without saving. As you press a key,
display will show the word "no SAVE".