"+" or "-" button and the right digit will flash; the default setting is zero, 1 minute will
be added to or decreased from the ice-making process for each pressing of the "+"
or "-" button. After 5 seconds, the new setting will be remembered by the system.
6.
Low water quality will cause low quality ice cubes and reduce the transparency of
the ice cube.
Automatic self-cleaning program
After connecting the water pipes, plug in the main power supply plug, then press and hold
the "Timer/Clean" button on the control panel for more than 5 seconds to enter the Self-
Cleaning program. The self-cleaning symbol will always be on during this period and the left
digit will indicate the remaining time. The total duration is 20 minutes for one self-cleaning
cycle. When the program is over, the system will enter standby mode automatically.
To force-cancel the cleaning program, press the "On/Off" button on the control panel during
a cleaning cycle.
Timer setting operation
Delay time range: 1-24 hours, Default time: 1 hour
Setting the On-Timer:
When the unit is in standby mode, press the "Timer/Clean" button to enable the timer. The
on-timer symbol will illuminate, and the number "1" above the symbol will flash to display the
set delay time. While this number flashes, press the "+" or "-" button to change the delay
time of the timer in 1-hour intervals for each press. After 5 seconds, the new setting will be
remembered by the system.
To cancel the timer, press the "Timer/Clean" button; the number above the on-timer symbol
will flash to display the present delay time. Press this button once again to cancel the Timer
setting, and the timer symbol and the number will disappear.
To force-cancel the timer, press the "On/Off" button on the control panel while the timer is
enabled.
Setting the Off-Timer:
When the unit is working, press the "Timer/Clean" button to set the timer. The off-timer
symbol will illuminate, and the number "1" above the symbol will flash to display the set
delay time. While this number flashes, press the "+" or "-" button to change the delay time of
the timer in 1-hour intervals for each press. After 5 seconds, the new setting will be
remembered by the system.
To cancel the timer, press the "Timer/Clean" button; the number above the on-timer symbol
will flash to display the present delay time. Press this button once again to cancel the Timer
setting, and the timer symbol and the number will disappear.
To force-cancel the timer, press the "On/Off" button on the control panel while the timer is
enabled.
Internal LED light operation