Emerson QuickPanel IC755C S06RD Series User Manual

Emerson QuickPanel IC755C S06RD Series User Manual

Hide thumbs Also See for QuickPanel IC755C S06RD Series:
Table of Contents

Advertisement

USER MANUAL
GFK 2847Y
Aug 2020
QuickPanel
+TM
OPERATOR INTERFACE
USER MANUAL
IC755CxS06RDx
(6" Display)
IC755CxW07CDx (7" Display)
IC755CxS10CDx (10" Display)
IC755CxS12CDx (12" Display)
IC755CxS15CDx (15" Display)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QuickPanel IC755C S06RD Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Emerson QuickPanel IC755C S06RD Series

  • Page 1 USER MANUAL GFK 2847Y Aug 2020 QuickPanel OPERATOR INTERFACE USER MANUAL IC755CxS06RDx (6" Display) IC755CxW07CDx (7" Display) IC755CxS10CDx (10" Display) IC755CxS12CDx (12" Display) IC755CxS15CDx (15" Display)
  • Page 2: Table Of Contents

    GFK-2847Y Aug 2020 Contents Chapter 1: Overview ............1 Specifications ....................2 1.1.1 Physical Specifications and Mounting Options ........2 1.1.2 Environmental Specifications .............. 7 Glossary ......................7 Revisions in this Manual ................8 PACSystems Documentation ................ 8 Chapter 2: Hardware ............
  • Page 3 GFK-2847Y Aug 2020 3.14.2 Enable or Disable SNMP Agent ............38 3.14.3 Export MIB to SD Card ............... 39 3.14.4 Load MIB into SNMP Manager ............40 3.14.5 Data Types Mapping between PAC Machine Edition Project and SNMP 3.14.6 Establish SNMP Communication ............41 3.15 ScreenSaver ....................
  • Page 4 GFK-2847Y Aug 2020 Chapter 6: Operation ............72 Touchscreen Display ................... 72 6.1.1 Display Brightness Adjustment ............72 6.1.2 Display Backlight Configuration ............73 6.1.3 Touchscreen Recalibration ..............73 Keyboard Configuration ................74 6.2.1 External Keyboard (Optional) ............74 6.2.2 Soft Input Panel ................74 Mouse ......................
  • Page 5 Changes, modifications, and/or improvements to equipment and specifications are made periodically and these changes may or may not be reflected herein. It is understood that Emerson may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time.
  • Page 6: Chapter 1: Overview

    User Manual Chapter 1 GFK-2847Y Aug 2020 Chapter 1: Overview Note: This manual specifically describes the QuickPanel IC755CxS06RDx, IC755CxWxxCDx and IC755CxSxxCDx display units. The QuickPanel Operator Interface is an all-in-one micro-computer designed for maximum flexibility. The design is based on an Advanced RISC Machine (ARM) core micro-processor to combine a high-resolution touchscreen operator interface with a variety of communications options.
  • Page 7: Specifications

    User Manual Chapter 1 GFK-2847Y Aug 2020 Specifications 1.1.1 Physical Specifications and Mounting Options IC755CxS06RDx Specifications Item Specification Processor Freescale i.MX535 (1 GHz ARM Cortex A8) DDR3 SDRAM 512 MB NAND FLASH 256 MB(IC755CxS06RDx-Ax) Memory NAND FLASH 512 MB(IC755CxS06RDx, -Bx, -Cx) SRAM 512 KB (with battery backup) Operating System...
  • Page 8 User Manual Chapter 1 GFK-2847Y Aug 2020 IC755CxW07CDx Specifications Item Specification Processor Freescale i.MX535 (1 GHz ARM Cortex A8) DDR2 SDRAM 512 MB (IC755CxW07CDx-Ax, -Bx, -Cx) DDR3 SDRAM 512 MB (IC755CxW07CDx-Dx, -Ex) Memory SLC NAND 256 MB (IC755CxW07CDx-Ax, -Bx, -Cx) SLC NAND 512 MB (IC755CxW07CDx-Dx, -Ex) SRAM...
  • Page 9 User Manual Chapter 1 GFK-2847Y Aug 2020 IC755CxS10CDx Specifications Item Specification Processor Freescale i.MX535 (1 GHz ARM Cortex A8) DDR3 SDRAM 1 GB Memory SLC NAND 512 MB SRAM 512 KB (with battery backup) Operating System Microsoft Windows Embedded Compact 7 Type 10.5"...
  • Page 10 User Manual Chapter 1 GFK-2847Y Aug 2020 IC755CxS12CDx Specifications Item Specification Processor Freescale i.MX535 (1 GHz ARM Cortex A8) DDR3 SDRAM 1 GB Memory SLC NAND 512 MB SRAM 512 KB (with battery backup) Operating System Microsoft Windows Embedded Compact 7 Type 12.1"...
  • Page 11 User Manual Chapter 1 GFK-2847Y Aug 2020 IC755CxS15CDx Specifications Item Specification Processor Freescale i.MX535 (1 GHz ARM Cortex A8) DDR3 SDRAM 1 GB Memory SLC NAND 512 MB SRAM 512 KB (with battery backup) Operating System Microsoft Windows Embedded Compact 7 Type 15"...
  • Page 12: Environmental Specifications

    User Manual Chapter 1 GFK-2847Y Aug 2020 1.1.2 Environmental Specifications Note: Install the QuickPanel in a well-ventilated location that is not exposed to dust, corrosive gases or liquids, rain, strong ultra-violet light or direct sunlight, and meets the following specifications. Item IC755CxS06RDx IC755CxW07CDx IC755CxS10CDx IC755CxS12CDx IC755CxS15CDx Cooling...
  • Page 13: Revisions In This Manual

    Video Electronics Standards Association Revisions in this Manual Date Description Following Emerson’s acquisition of this product, changes have been made Oct 2019 to apply appropriate branding and registration of the product with required certification agencies. No changes to material, process, form, fit or functionality.
  • Page 14 Field Agents User Guide GFK-2993 Field Agents Upgrade Guide GFK-3017 In addition to these manuals, datasheets and product update documents describe individual modules and product revisions. The most recent PACSystems documentation is available on the Emerson support website http://www.Emerson.com/Industrial- Automation-Controls. Overview...
  • Page 15: Chapter 2: Hardware

    User Manual Chapter 2 GFK-2847Y Aug 2020 Chapter 2: Hardware This chapter describes the QuickPanel hardware features, including physical characteristics and LED indicators. Physical Characteristics In addition to the primary touchscreen interface, the QuickPanel Operator Interface supports a variety of communication ports. The following diagrams illustrate the physical layout of the QuickPanel Operator Interface, including locations of status LEDs, communications ports, and connectors.
  • Page 16 User Manual Chapter 2 GFK-2847Y Aug 2020 Figure 3: Rear View & Dimensions IC755CxS06RDx Figure 4: 4-Sided View IC755CxW07CDx Hardware...
  • Page 17 User Manual Chapter 2 GFK-2847Y Aug 2020 Figure 5: Rear View IC755CxW07CDx Note: Refer to the section for drawing dimensions IC755CxW07CDx Specifications Figure 6: 4-Sided View IC755CxS10CDx Hardware...
  • Page 18 User Manual Chapter 2 GFK-2847Y Aug 2020 Figure 7: Rear View IC755CxS10CDx Note: Refer to the section for drawing dimensions. IC755CxS10CDx Specifications Figure 8: 4-Sided View IC755CxS12CDx Hardware...
  • Page 19 User Manual Chapter 2 GFK-2847Y Aug 2020 Figure 9: Rear View IC755CxS12CDx Note: Refer to the section for drawing dimensions. IC755CxS12CDx Specifications Figure 10: 4-Sided View IC755CxS15CDx Hardware...
  • Page 20: Led Indicators

    User Manual Chapter 2 GFK-2847Y Aug 2020 Figure 11: Rear View IC755CxS15CDx Note: Refer to the section for drawing dimensions. IC755CxS15CDx Specifications LED Indicators The QuickPanel Operator Interface provides LED indication for the following: • Operation status • Ethernet Port operation 2.2.1 Operation Status LEDs The QuickPanel...
  • Page 21: Ethernet Port Operation Leds

    User Manual Chapter 2 GFK-2847Y Aug 2020 2.2.2 Ethernet Port Operation LEDs The Ethernet port has two LED indicators: Speed and Link Activity. LED State Operating State Speed Yellow, on 10/100 Link Activity Green, on Link status Hardware...
  • Page 22: Chapter 3: Software

    User Manual Chapter 3 GFK-2847Y Aug 2020 Chapter 3: Software This chapter provides QuickPanel software information and procedures to perform the most common tasks. Operating System Note: Refer to http://windows.microsoft.com. The QuickPanel operating system (OS), Microsoft Windows Embedded Compact 7, is a full 32-bit OS with graphical user interface (GUI).
  • Page 23: Pac Machine Edition Project Update

    User Manual Chapter 3 GFK-2847Y Aug 2020 CAUTION Before disconnecting power, verify that the copy or update operation is complete (no busy message or wait cursor). To copy a PAC Machine Edition project to an SD card Verify that there is a blank SD card in the SD card port. Double tap the Copy Project to SD Card icon on the desktop.
  • Page 24: Remote User Authentication

    User Manual Chapter 3 GFK-2847Y Aug 2020 The FTP server is configured with the Quick Panel Setup Tool. By default, the server is not enabled. Once enabled, a background program will run, waiting for clients to connect. Up to ten connections are supported. Sessions that are idle for five minutes are terminated by the server.
  • Page 25: Sntp Server

    User Manual Chapter 3 GFK-2847Y Aug 2020 SNTP Server The SNTP server included with the QuickPanel supports SNTP Version 4 for IPv4, IPv6 and OSI. The SNTP server is configured with the QuickPanel Setup Tool. By default, the server is not enabled.
  • Page 26: Firmware Upgrade

    User Manual Chapter 3 GFK-2847Y Aug 2020 can be used to perform the following operations using the double-tap feature, without adjusting the DIP Switch positions: • Section 3.9.1, Firmware Upgrade • Section 3.9.2, Bypass Startup Programs • Section 3.9.3, Reset Enhanced Security •...
  • Page 27 User Manual Chapter 3 GFK-2847Y Aug 2020 To perform a firmware upgrade From the Start menu, select Programs, System, and QuickPanel OS Utilities Settings Tool to display the QuickPanel OS Utilities Settings window. Upgrade the firmware. Figure 12: Firmware Upgrade Sequence The operator interface guides the operator through the firmware upgrade process.
  • Page 28: Bypass Startup Programs

    User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 13: Firmware Upgrade Sequence for Specific Firmware Builds NOTICE • For a QuickPanel+ 7” inch Display unit, the following message displays during the process of firmware upgrade. You must re-run the QPPlusUpdate.exe program after reboot, which means you will run the QPPlusUpdate.exe program twice to complete the upgrade process.
  • Page 29 User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 15: Activate Checkbox for Use DIP Switch Figure 16: Enable Bypass Sequence Figure 17: Start-Up Window following Enable Software...
  • Page 30: Reset Enhanced Security

    User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 18: Start-Up Window following Disable If Use DIP Switch checkbox has been selected, don’t run Startup Programs displays on the startup window based on the position of DIP Switch 2. 3.9.3 Reset Enhanced Security The QuickPanel Operator Interface is configured using the PAC Machine Edition application.
  • Page 31: Enable Or Disable Snmp Agent

    User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 19: Sequence to Disable Reset Enhanced Security 3.9.4 Enable or Disable SNMP Agent The QuickPanel Operator Interface can be enabled as a Simple Network Management Protocol (SNMP) Agent with the capability to communicate with SNMP Managers for notification of Traps and responding to Query HMI Tag values.
  • Page 32: Display Screen Sensitivity Tool

    User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 21: Acknowledge SNMP Security Risk Notice NOTICE • SNMP communication is enabled on the device only after the user acknowledges this security dialog box (Figure 21) and clicks Yes. Note: Any failure or errors while enabling or disabling the SNMP service would be communicated to the user through a dialog box.
  • Page 33 User Manual Chapter 3 GFK-2847Y Aug 2020 Capacitive screens rely on the capacitive properties of the operator’s finger pressing lightly on the screen. If the operator is wearing gloves, this can affect the operation of the capacitive screens. The thickness of the glove keeps the operator’s finger slightly further from the screen. To accommodate gloved operation, the Sensitivity Tool allows the screen sensitivity to be set to a higher level.
  • Page 34: Launch Application

    User Manual Chapter 3 GFK-2847Y Aug 2020 3.11 Launch Application The Launch application window contains the shortcuts to launch some of the major QuickPanel Operator Interface applications. To launch an application Figure 24: Launch Application from Start Menu Figure 25: Select or Browse to Specific Application 3.12 VNC Server The VNC Server enables remote, visual connectivity to the QuickPanel...
  • Page 35: Battery Life Prediction

    User Manual Chapter 3 GFK-2847Y Aug 2020 The VNC Server is automatically launched during QuickPanel startup. It can also be launched manually from the Launch Application. To manually launch the VNC Server: from the Start menu, select Programs, System, Launch Application and start the VNC Server application.
  • Page 36 User Manual Chapter 3 GFK-2847Y Aug 2020 If the current time is not set on the device, the QuickPanel Setup Tool displays the following message stating that the current date and time must be set on the device to display the correct battery life prediction. Figure 28: Current Time Not Set Message After setting the current time, open the QuickPanel Setup Tool, and select the...
  • Page 37 User Manual Chapter 3 GFK-2847Y Aug 2020 If the option the battery is not present is selected, a message displays stating that battery life cannot be predicted without a battery installed on the device. Figure 31: Battery is Not Present Message If the option the battery was replaced is selected, enter the date of when the battery was first used in a QuickPanel device.
  • Page 38: Simple Network Management Protocol (Snmp)

    User Manual Chapter 3 GFK-2847Y Aug 2020 Close and re-open the QuickPanel Setup Tool dialog box to display the battery life prediction information. Figure 34: Close and Reopen Message Figure 35: Battery Life Prediction Example after Battery Replacement 3.14 Simple Network Management Protocol (SNMP) The SNMP is an application–layer protocol defined by the Internet Architecture Board (IAB) in RFC1157 that is used for exchanging management information between network devices.
  • Page 39 Figure 37 displays the MIB tree structure and the private enterprise number allocated by the Internet Assigned Numbers Authority (IANA) for the EMERSON SNMP products and OID for the QuickPanel MIB: •...
  • Page 40 User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 37: MIB Tree Structure NOTICE • It is highly recommended that you pre-load MIBs (GEIP-SMI.txt and GEIP-PRODUCTS- MIB.txt in sequence) prior to loading the QuickPanelMIB.mib file into SNMP Managers to avoid any MIB compiler errors. Download the MIBs GEIP-SMI.txt and GEIP-PRODUCTS-MIB.txt from the Support Site.
  • Page 41 User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 38: Alarm Trap Notification Display Figure 39 displays the list of HMI Tags that the SNMP Manager can query to retrieve live values from the HMI running on a QuickPanel device. Note: The list of all HMI tags is populated within the hmiTags node of MIB tree and the HMI Tag access level is currently restricted to Read-only for the SNMP Manager.
  • Page 42 User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 39: List of HMI Tags Available to Query The following sections provide the procedures to enable and configure the QuickPanel device to operate as an SNMP Agent and establish communication with an SNMP Manager. •...
  • Page 43: Configure Trap Destinations

    User Manual Chapter 3 GFK-2847Y Aug 2020 3.14.1 Configure Trap Destinations TRAP Destinations are configured through the QuickPanel Setup Tool by providing the IP Address of the SNMP Manager to which Traps should be sent. The user can configure two different Trap Destinations (IP Addresses).
  • Page 44: Export Mib To Sd Card

    Management Information Base (MIB) QuickPanelMIB.mib file to an SD Card. NOTICE • It is highly recommended that you pre-load Emerson MIBs (GEIP-SMI.txt and GEIP- PRODUCTS-MIB.txt in sequence) prior to loading the QuickPanelMIB.mib file into SNMP Managers to avoid any MIB compiler errors.
  • Page 45: Load Mib Into Snmp Manager

    User Manual Chapter 3 GFK-2847Y Aug 2020 Figure 42: Success/Failure Annunciation 3.14.4 Load MIB into SNMP Manager After successfully exporting the MIB to an SD Card, archive the QuickPanel MIB file to a folder on a machine running with SNMP Manager. To load the MIB into the SNMP Manager: •...
  • Page 46: Establish Snmp Communication

    This enables you to map to the DISPLAYSTRING data type in the SNMP communication as well. For example, for the Emerson SRTP driver, you can override the IO Address of LREAL variable LREALVar data type as %R100 [INT]. This maps LREALVar to DISPLAYSTRING in the MIB file.
  • Page 47: Screensaver

    User Manual Chapter 3 GFK-2847Y Aug 2020 If you get out of sequence in the steps for configuring Traps and starting the SNMP service to establish the SNMP communication, enable or disable the SNMP Agent again using the QuickPanel OS Utilities Setting tool. 3.15 ScreenSaver QuickPanel...
  • Page 48: Chapter 4: Pre-Installation Checks

    If the system received does not agree with your order, contact Customer Care. Before initial power-up, inspect the unit for loose or damaged components. If damage is found (such as bent component leads or loose components), contact Emerson Automation & Controls for additional instructions. CAUTION Do not apply power to the unit if it has visible damage.
  • Page 49: Basic Set-Up

    User Manual Chapter 4 GFK-2847Y Aug 2020 Figure 45: IC755CxWxxCDx Example Package Contents Basic Set-up The QuickPanel Operator Interface is shipped ready for use after initial configuration. To power up the unit, connect a dc power supply using the supplied quick-connect plug. Depending on the application, you may also want to connect and configure optional input devices, communications ports, and expansion adapters.
  • Page 50: Initial Start-Up

    User Manual Chapter 4 GFK-2847Y Aug 2020 Figure 46: Basic Setup Diagram Initial Start-up You will need the following: • Safety Extra Low Voltage (SELV) and Limited Energy Circuit or SELV and Class 2 dc power supply. • The power terminal block is supplied with the product. For voltage and requirements, refer to the Input Power specifications for each individual product in Section 1.1, Specifications.
  • Page 51: Initial Configuration

    User Manual Chapter 4 GFK-2847Y Aug 2020 Once power is applied, the QuickPanel begins initializing. The splash screen is the initial display. Figure 47: Power Input Connector To skip running any programs included in the StartUp folder: tap Don’t run Startup programs.
  • Page 52: Runtime Set-Up

    User Manual Chapter 4 GFK-2847Y Aug 2020 From the Control Panel, double-tap Network and Dial-up Connections to configure network settings. Run the Backup Utility to save the settings. Runtime Set-up To download an application to a QuickPanel Operator Interface, set up a data link between the unit and the development workstation.
  • Page 53 User Manual Chapter 4 GFK-2847Y Aug 2020 If you have not changed operating system settings (for example, brightness or touchscreen sensitivity), or do not want to save the changes, remove ac power from the dc supply. Run the Backup Utility to save changes to operating system settings. When the Backup window displays Completed Successfully, remove power from the dc power supply connected to the QuickPanel unit.
  • Page 54: Chapter 5: Mounting And Installation

    User Manual Chapter 5 GFK-2847Y Aug 2020 Chapter 5: Mounting and Installation This chapter provides the following procedures to mount and install the QuickPanel Operator Interface: • Protective Sheet Installation • Mounting Location • Panel Mounting • VESA Arm Mounting •...
  • Page 55: Panel Mounting

    User Manual Chapter 5 GFK-2847Y Aug 2020 Figure 49: Mount within 30 Degrees to Vertical Panel Mounting To mount the QuickPanel in an enclosure, you will need the following equipment: • One #2 Phillips head screwdriver • Mounting brackets (supplied) The mounting holes for IC755CxS06RDx, IC755CxW07CDx, and IC755CxS10CDx are located on the top and bottom edges of the unit.
  • Page 56 User Manual Chapter 5 GFK-2847Y Aug 2020 Figure 51: Mounting Holes (top & bottom edges) IC755CxW07CDx Figure 52: Mounting Holes (top & bottom edges) IC755CxS10CDx The IC755CxS12CDx and IC755CxS15CDx mounting holes are located on the top, bottom, and sides of the unit. Mounting and Installation...
  • Page 57: Mounting And Installation Procedure

    User Manual Chapter 5 GFK-2847Y Aug 2020 Figure 53: Mounting Holes (all four edges) IC755CxS12CDx Figure 54: Mounting Holes (all four edges) IC755CxS15CDx Mounting and Installation Procedure Observe the following guidelines to properly mount and install the QuickPanel Operator Interface: Note: To order replacement gaskets, refer to the part number listed in Appendix B:.
  • Page 58 User Manual Chapter 5 GFK-2847Y Aug 2020 • The unit will not fit through the cutout with any cables connected, or with the power supply plug inserted in the socket. CAUTION When installing the QuickPanel into the panel, pay careful attention while handling the unit so it does not drop and damage the unit.
  • Page 59 User Manual Chapter 5 GFK-2847Y Aug 2020 Figure 58: Panel Cutout Dimensions IC755CxS15CDx 2. Verify that the gasket is present and properly seated in the bezel channel located on the sides of the unit. 3. Insert the QuickPanel into the mounting panel cutout. Figure 59: Insert QuickPanel into Mounting Panel Cutout 4.
  • Page 60: Vesa Arm Mounting

    User Manual Chapter 5 GFK-2847Y Aug 2020 5. Tighten the screws on the mounting bracket in a clock-wise direction. Figure 61: Tighten Screws Torque Range for Mounting Clamp Screws Display Unit Torque Range IC755CxS06RDx 0.3 Nm (2.66 in-lb) IC755CxW07CDx 0.3 Nm (2.66 in-lb) IC755CxS10CDx 0.7 Nm (6 in-lb) IC755CxS12CDx...
  • Page 61: Battery Installation And Replacement

    User Manual Chapter 5 GFK-2847Y Aug 2020 Figure 62: VESA Mounting Holes IC755CxW07CDx or IC755CxS06RDx Figure 63: VESA Mounting Holes IC755CxSxxCDx Battery Installation and Replacement WARNING Batteries may present a risk of fire, explosion, or chemical burn if mistreated. Do not crush, disassemble, short-circuit, or dispose of in fire.
  • Page 62: Ic755Cxs06Rdx

    Machine Edition runtime. Attention 5.6.1 IC755CxS06RDx To install or replace the battery for IC755CxS06RDx: CAUTION Replace the battery for the IC755CxS06RDx only with Emerson battery part number IC755ACCBATT. Remove the battery cover by pressing down while sliding outward. Mounting and Installation...
  • Page 63 User Manual Chapter 5 GFK-2847Y Aug 2020 Figure 64: Battery Cover Removal IC755CxS06RDx Connect the battery harness connector to the header, noting keyed orientation. Figure 65: Battery Harness Connection IC755CxS06RDx Verify that the positive (red) is down and negative (black) is up. Wrap the harness connector around to match the following figure.
  • Page 64: Ic755Cxw07Cdx

    IC755CxW07CDx To install or replace the battery for the IC755CxW07CDx: CAUTION Replace the battery for the IC755CxW07CDx only with Emerson battery part number IC755ACCBATT. Remove the battery cover by pressing down while sliding outward. Figure 67: Battery Cover Removal IC755CxW07CDx Connect the battery harness connector to the header, noting keyed orientation.
  • Page 65: Ic755Cxsxxcdx

    Slide the battery cover into place, taking care not to pinch the harness connector. 5.6.3 IC755CxSxxCDx To install or replace the battery for the IC755CxSxxCDx: CAUTION Replace the battery for the IC755CxSxxCDx only with Emerson battery part number IC755ACCBATTNL. Mounting and Installation...
  • Page 66 User Manual Chapter 5 GFK-2847Y Aug 2020 Remove the screws (quantity 7) from the back cover. Figure 70: Screw Locations (Back Cover) IC755CxSxxCDx Gently press on either side tab to release the back cover. Figure 71: Release Cover by Pressing Side Tabs (IC755CxSxxCDx) Lift up and remove the back cover.
  • Page 67: Connectors

    User Manual Chapter 5 GFK-2847Y Aug 2020 Connectors 5.7.1 Power Connector Pin-Out for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx Note: Refer to Section 4.3.1, Connecting Input Power. Connector: Terminal Euro (Tyco Electronics 284539-3) Mating Connector: (Tyco Electronics 284510-3) Pin # Signal Name Pin-Out +24 Vdc 5.7.2 Ethernet for IC755CxS06RDx, IC755CxW07CDx, and...
  • Page 68: Serial Port Details

    User Manual Chapter 5 GFK-2847Y Aug 2020 IP Address Setting The QuickPanel Operator Interface provides two methods to set an IP address: • DHCP (Dynamic Host Configuration Protocol) The network server assigns an IP address during QuickPanel initialization. There must •...
  • Page 69 User Manual Chapter 5 GFK-2847Y Aug 2020 Pin # Signal Name Pin-Out Figure 73: Serial Port COM1 Pin-Out IC755CxS06RDx SGND IC755CxW07CDx Adhere to the following guidelines: • A terminal block is supplied with the unit. • The mating terminal block supports stranded 30 to 14 AWG (0.05 to 2.00 mm2) wires. •...
  • Page 70 User Manual Chapter 5 GFK-2847Y Aug 2020 Pin # Signal Name Pin-Out Figure 74: Serial Port COM1 Pin-Out IC755CxW07CDx SGND IC755CxSxxCDx Note: For an IC755CxS12CDA serial port, refer to Appendix C:, Serial Port Details IC755CxS10CDx, IC755CxS12CDA, and IC755CxS15CDx. Adhere to the following guidelines: •...
  • Page 71 User Manual Chapter 5 GFK-2847Y Aug 2020 Signal Pin # Pin-Out Name Figure 75: Serial Port COM1 Pin-Out IC755CxSxxCDx SGND Serial Port COM2 Details Interface: RS-232C/485 (default is RS-485 Half-duplex) Signal Name Pin-Out RS-485 RS-485 Pin # RS– (Full- (Half- Figure 76: Serial Port COM2 Pin-Out IC755CxSxxCDx 232C duplex...
  • Page 72 User Manual Chapter 5 GFK-2847Y Aug 2020 DIP Switch Settings COM2 for RS-232C DIPSW ON/OFF DIPSW ON/OFF DIP Switch Settings COM2 for RS-422 DIPSW ON/OFF DIPSW ON/OFF Figure 77: Example of Full-Duplex (RS–422 Mode) Connection Mounting and Installation...
  • Page 73: Universal Serial Bus (Usb) Ports

    User Manual Chapter 5 GFK-2847Y Aug 2020 DIP Switch Settings COM2 for RS-485 DIPSW ON/OFF DIPSW ON/OFF Figure 78: Example of Half-Duplex (RS–485 Mode) Connection 5.7.4 Universal Serial Bus (USB) Ports USB Host Port Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx The QuickPanel has two full-speed USB 2.0 host ports.
  • Page 74 User Manual Chapter 5 GFK-2847Y Aug 2020 Pin # Signal Name Pin-Out USB_VCC USB_D- USB_D+ USB_GND USB Device Port Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx The USB device port allows the QuickPanel Operator Interface to be used as Slave device. Interface: USB 2.0 Number of Ports: One Connector: Type-B Mini connector...
  • Page 75: Audio (Line Out) Details For Ic755Cxs06Rdx, Ic755Cxw07Cdx, And Ic755Cxsxxcdx

    User Manual Chapter 5 GFK-2847Y Aug 2020 5.7.5 Audio (LINE OUT) Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx Interface: LINE OUT (stereo) Number of Ports: One Connectors: Ø3.5 mm jack Maximum output level: 1 Vrms Pin # Signal Name Pin-Out Lineout R Lineout L 5.7.6 Audio (MIC IN) Details (Applicable only to...
  • Page 76 User Manual Chapter 5 GFK-2847Y Aug 2020 Figure 79: SD Card Location IC755CxS06RDx Figure 80: SD Card Location IC755CxW07CDx Figure 81: SD Card Location IC755CxSxxCDx Mounting and Installation...
  • Page 77: Chapter 6: Operation

    QuickPanel Setup tool available in the program system menu. CAUTION Although Emerson recommends the use of the protective sheet, do not operate the touchscreen with any hard materials, such as a screwdriver. This could damage the touchscreen display.
  • Page 78: Display Backlight Configuration

    User Manual Chapter 6 GFK-2847Y Aug 2020 6.1.2 Display Backlight Configuration To configure the display backlight Open the QuickPanel Setup Tool and select the Backlight tab to display the Backlight Display Properties window. Set the backlight to automatically turn off in a specific amount of time. Figure 83: Adjust Display Brightness Tap OK to exit the QuickPanel Setup Tool.
  • Page 79: Keyboard Configuration

    User Manual Chapter 6 GFK-2847Y Aug 2020 Figure 84: Touchscreen Sensor Calibration Switch Replace the battery cover. Keyboard Configuration The QuickPanel Operator Interface can be configured to use either or both a hardware keyboard and a software emulation keyboard as operator data input devices. Typically, an optional external hardware keyboard is used when in development mode, while the included Soft Input Panel (SIP) is more applicable in an operational environment.
  • Page 80: Printing

    User Manual Chapter 6 GFK-2847Y Aug 2020 Printing WARNING USB-connected printers will violate the electrical compliance ratings. They can only be used for maintenance and are not supported as a standard service. The QuickPanel Operator Interface supports printing with PCL v5 compatible laser and inkjet printers.
  • Page 81: Memory Allocation Modification

    User Manual Chapter 6 GFK-2847Y Aug 2020 CAUTION Setting the Program Memory too low may prevent additional applications from starting, or may cause currently running applications to fail due to lack of memory. Setting the Storage Memory too low may prevent the saving of files into the object store portion of the file system, which may also cause application failures.
  • Page 82: Chapter 7: Secomea Security (Optional)

    User Manual Chapter 7 GFK-2847Y Aug 2020 Chapter 7: Secomea Security (Optional) Secomea Configuration Tool Note: The SiteManager™ and its related GateManager™, LinkManager™ and LinkManager™ Mobile products are licensed, sold, and supported by Secomea and Secomea’s licensed distributors. Additional information is available at www.secomea.com. Secomea SiteManager software (also known as the Secomea Configuration tool) is installed on QuickPanel products.
  • Page 83 User Manual Chapter 7 GFK-2847Y Aug 2020 SiteManager is a device-monitoring front-end feature for multiple industrial devices on a location. Working with GateManager and LinkManager, it ensures uninterrupted and secure access to remote devices over the Internet or a private Wide-area Network (WAN) for all users.
  • Page 84 User Manual Chapter 7 GFK-2847Y Aug 2020 Figure 87: Secomea Products used with QuickPanel in Application Secomea Security (Optional)
  • Page 85: Chapter 8: Save And Restore Settings

    User Manual Chapter 8 GFK-2847Y Aug 2020 Chapter 8: Save and Restore Settings Save and Restore Settings enables to store the settings of certain parameters of QuickPanel to a file (the extension assigned to this file type is .qps) and then apply/restore the saved settings back to the same QuickPanel or any other QuickPanel from the saved .qps file,...
  • Page 86 User Manual Chapter 8 GFK-2847Y Aug 2020 Figure 89: QP Save Settings Settings tab Figure 90: QP Save Settings Registry Tab To update the value to a registry key the click on the Add button (Figure 90). This displays dialog (Figure 91) to enter the values for Key Path, Name, Type and value. After entering the values click the OK button to close the dialog, and the entered data may be viewed as a record in the Registry tab.
  • Page 87: Import Registry Data From Xml File

    User Manual Chapter 8 GFK-2847Y Aug 2020 Figure 91: Add Registry Key Dialog Box The entered data can be edited by selecting the record in the list box and clicking on the Edit button. This opens the dialog box that allows the user to edit the data. Figure 92: Registry List Display Import Registry Data from XML File An alternate method to input the data to the registry is by using the Import option where...
  • Page 88: Save The Settings To A File

    User Manual Chapter 8 GFK-2847Y Aug 2020 Figure 93: XML Schema for Registry On clicking the Import button, you may browse to select the xml file to be imported. Figure 94: Import XML Feature Note: The feature does not support editing any registry keys inside HKEY_CLASSES_ROOT. Save the Settings to a File To save the settings and registry values to a file, click on the Save button.
  • Page 89 User Manual Chapter 8 GFK-2847Y Aug 2020 Figure 95: Saving the Settings and Registry Values to a File Figure 96: Save Function Successful Notification Save and Restore Settings...
  • Page 90: Restore The Settings From A (.Qps) File

    User Manual Chapter 8 GFK-2847Y Aug 2020 Restore the Settings from a (.qps) File To restore the settings from a file to a QuickPanel , following steps need to be executed: 1. Make sure that the file is browsable from the target QuickPanel 2.
  • Page 91 User Manual Chapter 8 GFK-2847Y Aug 2020 Figure 99: Settings Restored Notification On clicking the Save or Restore button, an Enhanced Security enabled QuickPanel device will prompt the user for the Enhanced Security password. The corresponding operation will be executed only on successful authentication. Figure 100: Password Entry Required for Enhanced Security Enabled QP Save and Restore Settings...
  • Page 92: Appendix A: Product Certifications And Installation Guidelines

    User Manual Appendix A GFK-2847Y Aug 2020 Appendix A: Product Certifications and Installation Guidelines The QuickPanel Operator Interface is intended for use in industrial environments and, when properly installed, shall comply with the agency approvals listed in this document. Agency Approvals Note: The agency approvals listed in the following table and on the Declaration of Conformities are believed to be accurate;...
  • Page 93: Conditions Of Safe Use For Installation In Hazardous Locations

    User Manual Appendix A GFK-2847Y Aug 2020 Conditions of Safe Use for Installation in Hazardous Locations The following information applies to products bearing the UL marking for Hazardous areas and the ATEX marking for Zone 2 explosive atmospheres: • Suitable for use in Class I Division 2 Groups A, B, C, D; Class 2 Division 2 Groups F, G; Class 3 Division 1 and Division 2.
  • Page 94 User Manual Appendix A GFK-2847Y Aug 2020 Adjust the position of the retaining clamp by pushing the lever of the retaining clamp. Then close the retaining clamp to fit the cable size. Figure 103: Adjust Retaining Clamp • USB retaining clamp for IC755CSW07CDACA must be used in hazardous location installations as follows: Connect the USB retaining clamp plate.
  • Page 95: Emc Installation And Operation Considerations

    User Manual Appendix A GFK-2847Y Aug 2020 Adjust the position of the retaining clamp by pushing the lever of the retaining clamp. Then close the retaining clamp to fit the cable size. Figure 106: Insert Retaining Clamp into Retaining Clamp Plate WARNING •...
  • Page 96: Government Regulations

    Changes or modifications to this unit that are not expressly approved by Emerson could void the user’s authority to operate the equipment.
  • Page 97: Appendix B: Orderable Part Numbers

    QuickPanel Operator Interface Part Numbers Part Number Description IC755CSS06RDA QuickPanel 6” Color TFT with Resistive Touch Screen, Emerson Monogram Bezel, 24 Vdc Powered IC755CBS06RDA QuickPanel 6” Color TFT with Resistive Touch Screen, Blank Bezel, 24 Vdc Powered IC755ACC07GAS QuickPanel 6” Replacement Gasket...
  • Page 98: Appendix C: Serial Port Details Ic755Cxs10Cdx, Ic755Cxs12Cda, And Ic755Cxs15Cdx

    User Manual Appendix C GFK-2847Y Aug 2020 Appendix C: Serial Port Details IC755CxS10CDx, IC755CxS12CDA, and IC755CxS15CDx Adhere to the following guidelines: • A terminal block is supplied. • The mating terminal block supports stranded 30 to 14 AWG (0.05 to 2.00 mm2) wires. •...
  • Page 99 Note: If the product is purchased through an Authorized Channel Partner, please contact the seller directly for any support. Emerson reserves the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice.

Table of Contents