Stop using the tool immediately if any of the following problems occur. Serious
personal injury could occur. Any repairs or replacements must be done by a
qualified person or authorized service center only.
Problem
Excessive jams
Uneven clinch
Unclinched staple
Back to Top
1. Loosen screws and nut with an 8mm spanner and 4mm Allen wrench.
2. Remove the magazine assembly.
3. Loosen screws with 3mm Allen wrench
4. Change teeth one at a time to prevent reverse teeth.
Back to Top
CHICAGO
MINNEAPOLIS
FAX 1-800-295-5571

Troubleshooting

Warning
Cause
1. Teeth screws loose.
2. Wrong staple size.
1. Wrong staple size.
1. Teeth are loose or broken.

Teeth Replacement

LOS ANGELES
1. Tighten screws
2. Check staples
1.
Check for proper leg length
adjustment & clincher size.
1. Check & replace teeth as
needed.