Operating the tool
1. Remove plastic air inlet protective cap from air inlet as
shown in Fig. 4.
2. Prepare a ¼" male plug (not included) by applying seal-
ant tape to the threading, wrapping clockwise. Screw
threaded male air plug by hand into air inlet as shown
in Fig. 5 and tighten it with a wrench (not included) for
an airtight connection.
Note:
Do not overtighten! Sealant tape must be
used on this connection.
3. Push the control valve forward so that the end of the
valve protrudes out above the trigger for a clockwise
("forward") tool operation.
4. Push the control valve back so that the end of the valve
protrudes from the back of the housing for counter-
clockwise ("reverse") tool operation.
5. Adjust the air flow by pushing down the air regulator
and turning knob from positions 1 to 4 (Fig. 2), aligning
the desired number setting with the recessed arrow
(Pos. 1 = lowest amount of air flow; pos. 4 = highest
amount of air flow).
6. Push and snap the required ½" drive impact socket (not
included) onto the anvil.
Caution!
•
Keep tool pointed in a safe direction at all times.
•
Only use impact rated accessories with this tool. Other accessories may shatter, chip or crack
during operation.
•
Clean and inspect the tool daily. Carefully check for proper operation of trigger and safety mech-
anism. Do not use the tool unless both the trigger and safety mechanism are functional, if the
tool is leaking air or needs any other repair.
Maintenance
Regular maintenance
•
Clean and inspect the tool daily. Make sure the tool is disconnected from the air supply.
•
Blow the tool clean with compressed air and inspect for wear and damage. Use non-flammable
cleaning solutions to wipe the exterior of the tool, only if necessary. DO NOT SOAK the tool
with cleaning solutions. Such solutions can damage internal parts.
•
Inspect the trigger and the safety mechanism to ensure the system is complete and functional.
Check for loose or missing parts as well as parts that may be stuck.
•
Keep all screws tight. Loose screws may cause personal injury.
•
Place two or three drops of pneumatic oil (included) into the air inlet of the tool daily.
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
Item 61134
Page 8
05
2021-1