Connecting the UMI-7774/7772 to Drives and Other Devices

Voltage Considerations for the UMI-7774/7772

Do not connect the UMI-7774/7772 isolated power to a source greater than 30 V.
Caution
Doing so may cause damage to UMI-7774/7772 components.

Power Requirements

National Instruments UMI-7774/7772 User Manual
To cause current to flow through the input, the voltage applied to the
following types of inputs should be greater than 3.5 V and less than 30 V.
Fault inputs
Limit and home inputs
Global Stop inputs
Trigger inputs
General-purpose digital inputs
Also, the source must be able to provide at least 7.2 mA to turn on the
optical isolator and result in an ON condition. When the applied voltage
is below 2 V, the input results in an OFF condition.
Optical isolation is a method for transmitting a signal from its source to
a measurement device without a physical connection by using an optical
coupling technique. Optical isolation can help break ground loops in the
system and reduce the effects of noise and voltage transients.
The UMI-7774/7772 includes a 4-position power connector that provides
voltage and common for the main power supply as well as voltage and
common for the isolated output circuitry.