Vcc
UMI-7774/7772
© National Instruments Corporation
Chapter 3
Current Limiter
Figure 3-18. UMI-7774/7772 Optically Isolated Sourcing Digital Output Interface
Circuit and Connection to an External Load
Connecting Switches to UMI-7774/7772 Sinking
Inputs
Figure 3-19 shows an example of connecting a physical switch to a general
purpose Digital Input on the UMI-7774/7772. You can make the same type
of connection for the following UMI-7774/7772 sinking inputs:
•
Limits and Home
•
Triggers
•
Inhibit All
•
Shutdown
•
General-Purpose Digital Input
Connecting the UMI-7774/7772 to Drives and Other Devices
3-29
National Instruments UMI-7774/7772 User Manual
Viso
Current
Sense
Digital
Output
Load
Ciso