System Settings Page

The System Settings page (FIG. 101) sets the Secondary DNS Address information with its
corresponding IP communication parameters, NetLinx Master communication settings, and reads the
device number assigned to the Modero panel.
FIG. 101
System Settings page showing default values (reads and assigns values to the panel and Master)
The elements of the System Settings page are described in the table below:
System Settings Page Elements
Back:
Connection Status icon:
IP Settings:
DHCP/Static
IP Address
Subnet Mask
118
The data rate (in Mbps) at which the panel is currently communicating with a
target WAP at (dynamic).
• As you move closer to the target WAP (and both the signal strength/
quality), the data rate increases and as the quality degrades this rate
decreases.
• Data rates for 802.11g communication are: 1, 2, 5.5, 11, and 54 Mbps.
• Ex: 802.11g has a max data rate is 54 Mbps.
Saves the changes and returns you to the previously active touch panel page.
This visual display of the connection status allows the user to have a current
visual update of the panel's connection status regardless of what page is
currently active.
• A Lock only appears on the icon if the panel has established a connection
with a currently secured target Master (requiring a username and password).
Sets the IP communication values for the panel and contains:
Sets the panel to either DHCP or Static communication modes.
• DHCP (Dynamic Host Configuration Protocol) assigns IP Addresses from
client stations logging onto a TCP/IP network via a DHCP server.
• Static IP is a permanent IP Address that is assigned to a node in a TCP/IP
network.
Sets the secondary IP Address assigned to the panel.
Sets a subnetwork address to the panel.
• Subnetwork mask is the technique used by the IP protocol to filter messages
into a particular network segment (Subnet).
IP Settings section
Master Connection section
(NetLinx Master properties)
Master Connection features are not
saved until the panel is rebooted
Red
fields are user-editable
Blue
fields cycle through choices
Grey
fields are read-only