ARC-TX1
DMX512
DMX512 from
lighting console
Note:
TX1, you must use the ArcSystem comissioning tool software to add DMX fixtures.

RDM Values

Manufacturer ID: 0x6574 (Electronic Theatre Controls)
Model IDs
Product Type
ArcSystem D4 Drivers
Final Installation and Operation
ArcSystem wireless
luminaires
DMX512
ArcSystem wired
DMX luminaires
By default the TX1 DMX output is disabled. If you require DMX output from the
Third party
DMX devices
Description
Constant Current D4 Driver 150
Constant Current D4 Emergency Driver150
Constant Voltage D4 Driver 150, D4 Driver 350, and
D4 Driver 700 (wall-mount and rack-mount)
Constant Voltage D4 Emergency Driver 150, D4
Emergency Driver 350, and D4 Emergency Driver 700
Model ID
0x1204
0x1304
0x1205
0x1305