OPTIONAL FAN KIT INSTALLATION

FAN DUCT EXTENSION KIT INSTALLATION

FAN DUCT EXTENSION KIT
In order to use the fan extension duct kit, you must have
fan kit. This kit allows you to extend the fan duct to 9m.
1. Attach the connecting collar to the duct that came with the duct kit.
Use the screws provided.
WIRING DIAGRAM
Brown (Hot)
240 Volts
Blue (Neutral)
120 Volts
50 HZ
Copper (Earth)
60 Hz
Wire
Caution: Ensure that the wires do not touch any hot surfaces
and are away from sharp edges.
Alternate Switches: May use the following. Check with local authorities and electrician.
CLIPSAL 203 2E45 OUD - Dimmer
CLIPSAL 2031 VF3CSF - 3 Speed
919-637
Regency GF900C-1 Gas Fireplace
Rheostat
On/Off Switch
~
Wire Nut
Earth
2. Attach the 4.5m duct within this kit to the connecting collar on the opposite
end with the screws provided. Extend the fl ex to the desired length.
NOTE: The wires (in dotted lines)
and the wire nuts are not supplied.
Wire Nuts
Brown
Wire
Blue
Earth
Wire Nut
Black: High Speed
Heat Wave
Fan Assembly
3
GF900
installation
CAUTION: Label all wires prior to dis-
connection when servicing controls.
Wiring errors can cause improper and
dangerous operation
Wire Nut
Red: Low Speed
Fan
Black
White
Green
02.16.16