Testing Serial Control Commands - AMX Endeleo UDM-RX02 Operation/Reference Manual

Endeleo multi-format distribution mini-hub endeleo multi-format receiver
Hide thumbs Also See for Endeleo UDM-RX02:
Table of Contents

Advertisement

Testing Serial Control Commands

Device serial codes can be tested via options in the Status page, before they are added to the protocol
library.
Serial commands are stored in the UDM-RX02, and care should be taken to keep any
serially programmed units associated with the correct display device type.
The UDM-RX02 can store approximately eight serial commands per device, depending on the length of
the serial string.
1. Select Control from the options at the top of the Status page to access the Control page (see
FIG. 26 on page 25).
2. Select the Port hyperlink to access the Port Configuration page (FIG. 40).
FIG. 40
Port Configuration Page
3. Click on the Protocol drop-down menu and select Serial from the list of supported protocols to
enable the Serial-specific configuration options shown in FIG. 41.
FIG. 41
Serial configuration options
Any serial protocols that have been created previously are also available via this
drop-down menu. Refer to the Creating a Serial Protocol section on page 49 for
details.
4. Select the appropriate baud rate from the drop-down menu.
5. Click on Initialize to initialize the UDM-RX02.
UDM-0102 and UDM-RX02 Operation/Reference Guide
Select control protocol (Serial) here
Select Baud Rate
Click to initialize the UDM-RX02
Enter Serial command string
Test the entered command
Configuration
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Endeleo udm-0102