SATO CT4-LX Operator's Manual page 175

Hide thumbs Also See for CT4-LX:
Table of Contents

Advertisement

Low (with only liner) < 0.5 (V)
High (media attached with liner) - Low ≥ 1.0 (V)
The changes to this setting are linked and are changed with the settings in the [Tools] >
[Media Startup] menu.
[GAP Slice Level]
Set the Gap sensor slice level.
The setting procedure is as follows:
1. Use the following formula to calculate the slice level:
(High level - Low level) x 0.3 + Low level = slice level
2. Tap [GAP Slice Level] in the [Calibrate] menu.
3. Change the slice level value. Set the slice level to the level calculated in step 1.
4. Tap
to confirm the value.
If you set the slice level to 0.0 (V), the product sets the slice level automatically.
The changes to this setting are linked and are changed with the settings in the [Tools] >
[Media Startup] menu.
[I-Mark Levels]
Manually set the I-mark sensor level.
The setting procedure is as follows:
First, adjust the "Low" level (voltage) of the I-mark sensor.
1. Pass the media (attached with liner) above the I-mark sensor. Align it so that the I-mark sensor
does not detect the I-mark (black mark).
2. Close the top cover. To get the correct adjustment result, adjust after you have closed the top
cover.
3. Tap [I-Mark Levels] in the [Calibrate] menu.
4. Change the [Emit] value until the [Sensor] value is below 0.5 (V). Set the [Emit] value as low as
possible.
5. If the [Sensor] value does not decrease below 0.5 after you changed the [Emit] value, change the
[Receive] value.
6. Take a note of the [Sensor] value from the above procedure. This is the "Low" level value for the I-
mark sensor.
Next, check the "High" level (voltage) of the I-mark sensor as follows:
1. Pass the media above the I-mark sensor so that the I-mark sensor can detect the I-mark (black
mark).
2. Close the top cover.
175