▲ Interface
1. Main Interface:
DMX:
T:
\ First Line: DMX address, current pressure value
\ Second Line: inner core temp. delayed firing time
The working principle of the machine is when the firing is triggered, it takes some time (jet
delay) for the system to transfer and stimulate the consumables. When it reached the
delayed firing time, the valve will open automatically and firing activated.
2. Error information:
Error information
E0 System IC
E1 Pump Protect
E2 Temp. Sensor
E3 P Temp. Over
E4 Time Remain
E5 K Temp. Over
E6 Heat Fail
E7 Tip Over
SHOWVEN SPARKULAR JET USER MANUAL -3-
11
P:
19
Delay:
0.9s
Explanation
1.Emergency stop was executed when firing was triggered, and
firing stops. E0 disappear automatically 1min later. Too frequent
firing in a short period of time, E0 disappear 100s later.
It happens when continuous pressurization fail, probably the
pump was malfunction.
Temperature sensor is not connected or damage
Chassis over-temperature
Activated time for machine is not enough, need to swip RFID
card
Inner core over-temperature
Heating fail, if recover automatically, please pay attention to the
power supply.
Slant over 45 degree, machine stops firing automatically