Piper Comanche PA-24 Service Manual page 679

Hide thumbs Also See for Comanche PA-24:
Table of Contents

Advertisement

PIPER COMANCHE SERVICE MANUAL
.... ClA'
I~
TO ... All . . "
FIGURE 9·9. CUTOUT REU.Y
AIR GAP CHECK AMD ADJUSTMENT
current
now
to
the
required
1IID0UDt.
STOll
FIGURE 9·10. CUTOUT RE I..AY
POINT OPENING CHECK AHD ADJUSTMENT
Allow lenerator to operate at this speed aDd current flow for 15 minu.tes with relulator
cover in place
in
orcI.er to bring the voltage reculator to operatinC temperature.
e. Cycle the &enerator
by
either method listed in Step (el of "Fixed Resistance
~ethod"
of
"Volta. Setting"
~oced\Ue.
f. "ote the thermometer re.:!ing and select the uNormal Range" of voltage for this tempera-
ture as listed
ttl
specificatia1s paragraph 9-41.
g. Note the voltmeter reacUnl with relu.lator cover in place.
h. Adjust volt .. e resWator .. required .. described
in
Step
(h)
of "Fixed Resistance Method"
of "Voltag. Setting Procedure." In usiag the v.iable resistance method.
it
is necessary to re-
adjust the vuiab1e resistance after each yoltate adjustment to assure that 8-l0 amperes are
flowing. Cycle &eneratar after eacb adjustment before
readine
voltage regulator setting
with
cover
in place.
9-34. C .. tout Relay. The
cutout
relay requires three
checks
and
adjustments:
air gap.
point
Openinl,
and. closing voltage.
The
air
gap and
point
open1tl&
ildjustments
must be made
with
the
battery disconnected.
8.
Air Gap - Place fingers
CIl
armature d.irectly above core
and move
armature down until
points just
close
and tben measure air cap between. armature and center
ot core
(Figure 9-9). On
multiple ccmtact point relays. make sure tbat all points close simultaneously. If they do
i10[,
bend
sprinl finler so they do. To adjust air IIIP, loosen t"Wo screws at the back of relay and :-aise or
lower
the
arm8Uue as required. Tichten screws after adjustment.
b. Point Opening - Check POUlt openmg and adjust
by
bending the upper armature stop (Figure
9-10).
c. Closing Vo1tale - Connect reaulator to proper generator and battery. Connect voltmeter
between the regulator "GEN" terminal and ground (Figure 9-11).
~Iethod
1 - Slowly increase generator speed and note relay clos1D.1 voltage. Oec:ease
3 83
EI..ECTRICAI. SYSTEM
ISSUED:
8/18172

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comanche pa-24-250Comanche pa-24-260Comanche pa-24-400

Table of Contents