PIPER COMANCHE SERVICE MANUAL
TABLE V·II. TROUBLESHOOTING OIAAT (SURFACE CONTROLS) (CODL)
Trouble
Flaps not synchronized
or
fail
to fit
evenJy when
reo-
<n=d.
Slugish or retarded
flap retraction.
Flap actUating sy .. om
fails
to shut-off when
flaps are full up or
full down.
Righr
tlaf>
fails to lock
when in the rem.cted
position.
SURFACE CONTROLS
ISSUED: 8118172
Ca_
FLAP CONTROL SYSTEM (conL)
Inconect
riainI.
Weak retraction .pring
(PA·24-2'0 up to Serial
24-3444 inclusive).
The limit switches &re
out of adjustlllenL
Flap acruaa,. cable hu
insufficient .lack.
Spring on flap locking
mechanism broken.
IHI0
Remedy
Rig in accordance with
Pangraph
,·19
or
5-23.
Refer to Piper Service
Letter No. 39' and
insuJI spring So.
83302·54.
Reset
lim it
switches.
(Ref .. to pangraph
5·19 or '·23.)
Rerig up lock cable.
(Refer to parograph
H9
or '·23.)
Replace spring.
.
~