Piper Comanche PA-24 Service Manual page 190

Hide thumbs Also See for Comanche PA-24:
Table of Contents

Advertisement

Flood Damage, Immersion in Water (continued)
E.
Item
Vacuum and Pitot-Static
Systems.
Induction System.
Fuel System.
Instruments.
Heating and Ventilating
Systems.
Oxygen System
(If installed.)
III - INSPECTION
PIPER COMANCHE SERVICE MANUAL
Replace gyros.
Replace filters.
Clean and inspect all lines, and pitot
and static vents.
Clean and check all regulating valves.
Remove and inspect engine driven and
auxiliary vacuum pumps.
Clean and inspect for silt and
corrosion. Check all ducts and gaskets.
Replace as necessary.
Clean and inspect all heat shrouds
and ducting.
Perform Fuel Tank/Wing Spar Corrosion
Inspection. Remove and clean
fuel cells and fuel cells wing area. Clean
all associated lines and pumps.
Clean and inspect all fuel tank vents,
cap vents and vent lines.
Clean and inspect instruments. Bench
check per appropriate maintenance
manual.
Replace blower.
Clean and inspect all distribution boxes,
ducting and valves.
Inspect and check system control cables.
Replace corroded or binding cables.
If installed, clean and inspect air
conditioning evaporator, condenser,
and compressor.
Disconnect all lines from source and
outlets; clean all fittings and lines
per MIL-I-5585A.
Remove and clean regulator valve per
appropriate Scott publication.
Replace pressure gauge.
Replace oxygen generator units.
Inspection
1D52
Inspection Interval
If immersed, each event,
before further flight.
If immersed, each event,
before further flight.
If immersed, each event,
before further flight.
If immersed, each event,
before further flight.
If immersed, each event,
before further flight.
If immersed, each event,
before further flight.
04/01/09

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comanche pa-24-250Comanche pa-24-260Comanche pa-24-400

Table of Contents