Active Line Modules; Description - Siemens Sinamics S120 Manual

Liquid-cooled chassis power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

5.3

Active Line Modules

5.3.1

Description

The self-commutating infeed / regenerative feedback units act as step-up converters and
generate a stabilized DC link voltage that is 1.5x greater (factory setting) than the rated line
supply voltage. In this way, the connected Motor Modules are isolated from the line voltage.
This improves the dynamic response and control quality because line tolerances and
fluctuations do not affect the motor voltage.
If required, the Active Line Modules can also provide reactive power compensation.
Table 5- 12
Overview of Active Line Modules
Frame size GXL
Liquid-cooled chassis power units
Manual, (GH7), 11/2016, 6SL3097-4AM00-0BP7
Frame size HXL
Line Modules
5.3 Active Line Modules
Frame size JXL