Siemens Sinamics S120 Manual page 307

Liquid-cooled chassis power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Table 8- 6
Required fan flow rate through the power unit for degree of protection > IP21
Type
Power Module FL, 210 A (400 V)
Power Module FL, 260 A (400 V)
Power Module GL, 310 A (400 V)
Power Module GL, 490 A (400 V)
Basic Line Module FBL, 740 A (400 V)
Basic Line Module FBL, 1220 A (400 V)
Basic Line Module GBL, 1420 A (400 V)
Basic Line Module FBL, 420 A (690 V)
Basic Line Module FBL, 730 A (690 V)
Basic Line Module GBL, 1300 A (690 V)
Basic Line Module GBL, 1650 A (690 V)
Active Line Module GXL, 490 A (400 V)
Active Line Module HXL, 840 A (400 V)
Active Line Module HXL, 575 A (690 V)
Active Line Module JXL, 1422 A (690 V)
Motor Module FXL, 210 A (400 V)
Motor Module FXL, 260 A (400 V)
Motor Module GXL, 310 A (400 V)
Motor Module GXL, 490 A (400 V)
Motor Module HXL, 605 A (400 V)
Motor Module HXL, 674 A (400 V)
Motor Module HXL, 840 A (400 V)
Motor Module JXL, 985 A (400 V)
Motor Module JXL, 1405 A (400 V)
Motor Module FXL, 100 A (690 V)
Motor Module FXL, 150 A (690 V)
Motor Module FXL, 215 A (690 V)
Motor Module FXL, 330 A (690 V)
Motor Module HXL, 465 A (690 V)
Motor Module HXL, 575 A (690 V)
Motor Module HXL, 735 A (690 V)
Motor Module HXL, 810 A (690 V)
Motor Module JXL, 810 A (690 V)
Motor Module JXL, 1025 A (690 V)
Motor Module JXL, 1270 A (690 V)
Motor Module JXL, 1560 A (690 V)
Recommended fan: EBM-Papst, type W2E200-HH38-01
Liquid-cooled chassis power units
Manual, (GH7), 11/2016, 6SL3097-4AM00-0BP7
8.3 Cabinet installation, vertical and horizontal installation
Required volumetric flow dv/dt of roof-
mounted fan [m³/s]
0.003
0.003
0.004
0.006
0.010
0.017
0.024
0.009
0.016
0.018
0.023
0.006
0.010
0.006
0.024
0.002
0.003
0.004
0.006
0.007
0.008
0.010
0.020
0.026
0.002
0.003
0.004
0.005
0.006
0.007
0.018
0.018
0.019
0.021
0.024
0.038
Cabinet design and EMC
Average rate of flow
[m/s]
0.01
0.02
0.02
0.03
0.05
0.09
0.12
0.05
0.08
0.09
0.12
0.03
0.05
0.03
0.12
0.01
0.02
0.02
0.03
0.04
0.05
0.05
0.10
0.14
0.01
0.02
0.02
0.03
0.03
0.03
0.1
0.1
0.10
0.11
0.12
0.21
307