Active Line Modules; Description - Siemens SINAMICS S120 Equipment Manual

Chassis liquid cooled power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Line Modules

4.3 Active Line Modules

4.3
Active Line Modules
4.3.1

Description

The self-commutating infeed / regenerative feedback units act as step-up converters and
generate a stabilized DC link voltage that is 1.5x greater (factory setting) than the rated line
supply voltage. In this way, the connected Motor Modules are isolated from the line voltage.
This improves the dynamic response and control quality because line tolerances and
fluctuations do not affect the motor voltage.
If required, the Active Line Modules can also provide reactive power compensation.
Table 4- 12
Overview of Active Line Modules
Frame size GXL
108
Frame size HXL
Frame size JXL
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1

Advertisement

Table of Contents
loading

Table of Contents