Technical Data - Siemens Sinamics S120 Manual

Liquid-cooled chassis power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Motor-side power components
7.1 Sine-wave filter
7.1.4

Technical data

Table 7- 2
Technical data of sine-wave filters 380 V ... 480 V 3 AC
Article number
Suitable for Power Module
Suitable for Motor Module
Rated current (unit rating) of the
Power Modules or Motor Mod-
ules with sine-wave filter
at pulse frequency of 4 kHz
Rated current
Maximum output frequency
Power loss
- At 50 Hz
- At 150 Hz
Connections
- to the Power Module or Motor
Module
- load
Max. permissible cable length
between sine-wave filter and
motor
Degree of protection
Dimensions
Width
Height
Depth
Weight
248
6SL3000-
2CE32-3AA0
6SL3315-
1TE32-1AAx
6SL3325-
1TE32-1AAx
170 A (90 kW)
A
225
Hz
150
kW
0.35
kW
0.6
m
IP00
mm
620
mm
300
mm
320
kg
124
2CE32-3AA0
2CE32-8AA0
1TE32-6AAx
1TE33-1AAx
1TE32-6AAx
1TE33-1AAx
215 A (110 kW)
270 A (132 kW)
225
276
150
150
0.35
0.6
0.69
M10 connecting lugs
M10 connecting lugs
300 (shielded)
450 (unshielded)
IP00
IP00
620
620
300
300
320
320
124
127
Manual, (GH7), 11/2016, 6SL3097-4AM00-0BP7
2CE34-1AA0
1TE35-0AAx
1TE35-0AAx
380 A (200 kW)
408
150
0.4
0.38
0.7
IP00
620
370
360
198
Liquid-cooled chassis power units

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simanics s120