Chapter 2 Useful Features
2.3.6

ECO

The ECO menu appears when you select ECO on the BMC Configuration menu.
The table below shows details of parameters and their default values.
Item
Reference Values
Maximum Power
Consumption
Minimum Power
Consumption
Statistics Values
Power Supply
CPU Throttling
Memory Throttling
Configuration
Aggressive Mode
Power Threshold(Pa)
Correction time limit
Shutdown System
Non- Aggressive
Mode
Displays reference values of power consumption.
Shows the minimum power consumption. *1
Shows the minimum power consumption. *1
Shows statistic value for each item.
Statistic values for all items can be obtained by selecting "<Reload>".
Statistic value of each item can be cleared by selecting "<Reset xxxxx
statistics>".
Shows Current / Maximum / Minimum / Average power consumption (Watt).
Shows Current / Maximum / Minimum / Average CPU throttling rate. *2
Shows Current / Maximum / Minimum / Average memory throttling rate. *2 *3
Enable or disable Aggressive Mode.
Specify power threshold in Aggressive Mode.
Allowable range is between AAA and Operating power at maximum
configuration (Watt). *4 *5
When power consumption exceeds the power threshold for Aggressive Mode
and unable to recover within the time period specified in this parameter, collects
event log, sends an alert, and shuts down the system.
Allowable value (in seconds) depends on system. *4
Enable or disable the feature to shutdown the system when power consumption
exceeds the time specified in Correction time limit. *4
Enable or disable Non-Aggressive Mode.
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
ECO menu
Description
2. BMC Configuration
(1/2)
Default Value
Disable
Operating power at
maximum
configuration
The larger value
comparing with 2
and Minimum
system value
Disable
Disable