NEC Express 5800 Series Maintenance Manual page 140

Express server
Hide thumbs Also See for Express 5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
BIOS Message on
Upper LCD Line
System
Configuration
change is detected
PCI Slot #x
Uncorrectable
Error (x: 1-2)
(Express5800/T110
f-S, T110f-E)
PCIxx Slot
UnCorrectable
Error (xx: 1A, 1B)
(Express5800/R110
f-1E)
PCI-Express
Uncorrectable
Error 1
DIMM #x
Correctable Error
(x: 1-4)
DIMM #x
Uncorrectable
Error (x: 1-4)
Memory
Reconfigured
140
Description
The CPU or memory configuration
has changed since the previous
startup.
An uncorrectable error occurred in
PCI slot #x.
An uncorrectable error occurred in
PCI slot #xx.
An uncorrectable device error
occurred in PCI Express.
A correctable memory error occurred
in DIMM #x.
An uncorrectable memory error
occurred in DIMM #x.
A failed DIMM was detected and
degraded.
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
Action
If this message appears even when no configuration
change has been made, contact your sales
representative
Install the PCI boards correctly. If the error is detected
again, contact your sales representative.
Contact your sales representative.
The error was corrected. If the same error occurs after
restarting, install the DIMM correctly. If the error is
detected again, contact your sales representative.
Contact your sales representative.
Contact your sales representative.
1. POST Error Message