Chapter 2 Useful Features
(2) Power Control Configuration submenu
On Server, choose Power Control Configuration and then press <Enter> key to show its submenus.
AC-LINK
Power On Delay Time Mode
Delay Time
Standby Power Save
Cold Redundant Mode
(Express5800/T110f-E)
Option
Parameter
Stay Off
[Last State]
Power On
[Manually Setting]
Random
[xx]-600
[Disabled]
Enabled
[Disabled]
Enabled
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
Description
Specifies how the power state should be when the AC
power is supplied again after the power is lost.See the
table below.
Selects a method to specify the delay time before
powering on DC power.
This option is selectable when Power On or Last
State is specified in AC-LINK.
Specifies the waiting time before powering on DC
within the range between "xx" and 600 seconds.
This feature is enabled when Power On or Last State
is specified in the AC LINK setting.
"xx" indicates the minimum configurable time and is
displayed when executing Load Setup Defaults. If
Save Changes and Exit is selected with a value
smaller than the minimum value specified, the
minimum configurable time is automatically applied.
Enables or disables the feature that saves the standby
power on standby.
If this option is enabled, the AC-LINK setting is fixed to
Power On and cannot be changed.
Enables or disables cold redundancy.
This option is displayed only when using redundant
power supply.