Chapter 1 Maintenance
[?]
Event ID505: If the N8103-154/ 155/162 extra battery is mounted, the following message may be registered
in the RAID log of Universal RAID Utility and OS logs (Windows event log, Linux syslog)
Event source : raidsrv
Event ID
Type
Description
If the above event is registered, check the Cache Mode (current value) of the RAID Controller with Universal
RAID Utility.
If the Cache Mode (current value) is Write Back, use the battery as is because there is no problem.
If the Cache Mode (current value) is Write Through, the battery refresh operation causes the battery
temperature to rise temporarily. This event temporarily stops the refresh operation, so the battery
temperature drops and the refresh operation resumes. However, it may take time till the temperature
drops. After the refresh operation is completed, the Cache Mode (current value) changes to Write Back.
If the Cache Mode does not change to Write Back although 24 hours have elapsed, the battery may be
faulty. Replace the battery.
[?]
Event ID508: If the N8103-154/155/162 extra battery is mounted, the following message is registered in the
RAID log of Universal RAID Utility and OS logs (Windows event log, Linux syslog)
Event source : raidsrv
Event ID
Type
Description
Did the battery become unstable immediately after the extra battery had been mounted?
Immediately after the extra battery is mounted, this event may be registered till the battery refresh
operation is completed.
If this message is registered, wait for about 15 minutes and check the Cache Mode (current value) of the
RAID Controller. If the Cache Mode (current value) is Write Back, use the battery as is because there is no
problem.
If the current cache mode is set to "Write Through", the battery needs to be refreshed. Contact your
service representative.
If "Write Through" is retained for 9 hours or more after starting refresh operation, the battery may be
faulty. Replace the battery.
[?]
Event ID510: The following event is logged in RAID log of Universal RAID Utility and OS log (Windows
event log or Linux syslog) when additionally battery is installed.
Event source : raidsrv
Event ID
Type
Description
Use Universal RAID Utility to perform battery refresh manually. See Universal RAID Utility User's Guide
stored in EXPRESSBUILDER for more information.
34
: 505
: Warning
: <RU0505> [CTRL: Number of RAID Controller] Temperature of battery
is high.
: 508 (800001FC)
: Warning
: <RU0508> [CTRL: Number of RAID Controller] The battery status is
unstable.
: 510
: Info
: <RU0510> [CTRL: Number of RAID Controller]
Battery Refresh required.