GAS SPECIFICATIONS

GAS TYPE
Maximum gas consumption
Injector onfice diameter
Number of injectors
Regulator pressure
NOTES:
This appliance MUST be installed and serviced only
by a qualified licensed person.
This product is intended for outdoor use only.
Connecting the appliance to an LPG gas supply
This barbecue is set up for LPG gas and is labelled
accordingly. A Natural gas conversion kit is available
as an accessory if required.
The appliance may be supplied LPG from either
A 9kg portable cylinder, or
A remote supply of via fixed pipe work.
4 BURNER
5 BURNER
UNIVERSAL LPG
UNIVERSAL LPG
68 MJ/h
85 MJ/h
ø 1.15 mm
ø 1.15 mm
4
2.75 kPa
2.75 kPa
Connecting the appliance to a LPG gas cylinder
Gas bottle safety information
Connecting to a remote supply of LPG
Fitted semi-rigid
appliance pipe
Gas connection.
3/8" SAE Flare with
5/8-18 UNF thread
Fitted LPG gas bottle
hose & regulator
4 BURNER
NATURAL
GAS
68 MJ/h
ø 1.90 mm
5
4
1.0 kPa
The appliance has a 9kg gas bottle regulator and hose
already fitted.
Connect the POL fitting of the inlet of the regulator to
the valve on the LPG cylinder.
Carry out a leakage check.
This appliance, when connected directly to an LPG
cylinder, the cylinder capacity shall be 9kg(20lbs).
The gas cylinder must be made and marked in
accordance with specifications for LPG cylinders.
It is recommended to turn off the cylinder valve when
the appliance is not in use.
Gas cylinders must be stored in an approved housing out
of reach of children.
When disconnecting the gas bottle ensure that all the
control valves are in the 'OFF' position.
Remove the bottle from any housing in which it may be
stored before disconnection.
When reconnecting the hose to the bottle, ensure that
all connections are tight before replacing in the storage
compartment.
Carry out a leakage check.
The appliance shall be installed in accordance with
AS/NZS5601 gas installations and any relevant local gas
fitting rules.
Remove the gas bottle hose and regulator from the
appliance pipe.
Connect the consumer supplied fixed LPG pipework to
the appliance pipe.
Carry out a leakage check on all connections.
5 BURNER
NATURAL
GAS
85 MJ/h
ø 1.90 mm
5
1.0 kPa
7
GAS SPECIFICATIONS