SENSORVISION PRODUCTS SpeedDome Optima Quick Reference Manual page 9

American dynamics speeddome optima: service manual
Table of Contents

Advertisement

Required Parts
Required Parts
Required Parts
Adjustable I-Beam Clamp Install Kit
0351-0391-01
Description
Q t y .
Base plate
1
Clamp plate
2
Screw, mach. M6x70
4
Washer, flat
12
Nut, locking
8
Fitting, pipe nipple
1
Fitting, pipe tee
1
Flange, 1-1/4"
1
Procedure
I-beam attachment
[a] against a suitable ceiling member [b].
Secure the plate using clamps [c] and
hardware supplied [d]—see base plate
hole-to-hole dimensions, below. Attach the
flange [e] using hardware supplied [f].
[b]
[c]
[a]
[e]
Base plate
[f]
hole-to-hole
dimensions
90mm
(3.5")
128mm (5")
179mm (7")
230mm (9")
*
U.S. Customary Measurements in italics are rounded off.
Part No.
0500-3975-01
0500-3976-01
5801-4194-311
5840-0500-020
5826-0500-020
1417-0041-01
1417-0040-01
1400-0069-01
. Set the base plate
[d]
6.1M (20') MAX
30.4cm
(12")
Vertical/Horizontal mounting.
nipples [g] and [h] into the pipe tee [i], and
screw the entire assembly into the base [j].
Next, feed video and multiconductor cables
[k] through center hole of pipe tee. Note:
Remove the Cinch-Jones connector, if used,
to enter pipe.
Finally, thread the housing [l] onto the pipe.
See chassis installation on page Q-8.
Horizontal
Mounting
[j]
[g]
Note:
with pipe, cable exiting pipe tee
[k]
must be no farther than 15.2cm
[i]
(6") from I-beam clamp.
[l]
SENSORVISION SpeedDome
*
35.6cm
(14") MAX
Thread
If replacing pipe tee
Q-7