6
Squeeze the spring-loaded ejector pins [n] together to
seat the chassis in the corner receptacles [o]. The
RS422 board [p] must face the SpeedDome interface
board cables [q] inside the housing.
7
Set the thumbwheel switches [r] to the appropriate
address. Example: for address 16,
MSB LSB
1
P3
Alarm
Input
8
Then, with the camera chassis hanging down,
connect the video and data SpeedDome Interface
Board cables [q] to their receptacles [s]. Do not
use the alarm input connector [t].
9
To lock the chassis in the housing, squeeze ejector
pins [u] and swing the chassis all the way up, while
easing the cables into place. Release these pins
into the remaining corner receptacles.
ENSURE EJECTOR PINS ARE FULLY
INSERTED IN THE RECEPTACLES.
10
Snap the four pins of the skirt assembly [v] into the four
chassis receptacles [w]. Then screw the attachment screws
of the bubble [x] into the three housing receptacles [y].
11
To compensate for accidental jarring during assembly,
recalibrate the dome as follows:
a.
At the console, call up the dome address
number.
b.
Press and hold the fast key. Then—in order—press
and hold the zoom out, focus far, and iris open keys.
When the dome begins to pan and tilt, release the keys.
Once calibrated, which takes about a minute, the dome
is ready for use.
J1
6
P4
AC and
Video
Data
DOME INSTALLATION IS COMPLETE.
To connect alarm to
an outdoor Speed-
Dome, add lightning
protection using a
dataline protector,
PN 4815-0021-01.
[o]
[q]
[p]
[n]
[w]
[v]
[x]
SENSORVISION SpeedDome
[y]
[t]
[r]
[s]
[u]
Q-17