No Tilt Function - SENSORVISION PRODUCTS SpeedDome Optima Quick Reference Manual

American dynamics speeddome optima: service manual
Table of Contents

Advertisement

No Tilt Function

What to check.
1.
Connection to P1.
2.
Sprocket.
3.
Tilt motor when the tilt function is
commanded.
4.
Data when the tilt function is
commanded.
What to do.
Reset the dome and observe the orientation
(tilt). Verify that the motor is connected to P1
on the camera/lens board.
Check to see if the sprocket moves freely and
adjust it accordingly. If the motor gear is too
tight, adjust the gap distance of the sprocket
and gear with a 1/4 watt resistor lead. See
page Q-38.
Plug a known working tilt motor into P1. If the
motor works with the tilt command, replace
the tilt motor. If the tilt motor does not work,
replace the camera/lens board.
If no data is present, check the data path for
improper wiring.
NOTE: Tilt motors are not interchangeable
with other motors.
SENSORVISION SpeedDome
Q-25

Advertisement

Table of Contents
loading

Table of Contents