9

Interface Specification

The F-100 SR interface is RS-232C (D-sub 9pin), RS-232C (Loose end) or USB (COM/HID).
9.1

RS-232C Interface (D-Sub 9pin)

9.1.1 Initial Communication Settings
Basic communication specs are as follows.
Item
Baud rate
Data length
Parity bits
Stop bits

9.1.2 Signal Specification

Signal names are based on the signals transmitted from the scanner to the host.
Signal Level RS-232C communication line
Signal Name
TxD
RxD
RTS
CTS

9.1.3 Pin Assignment

Signal Name
Pin No.
(NC)
TxD
RxD
(NC)
GND
(NC)
CTS
RTS
(NC)
SPECIFICATIONS MANUAL
Communication spec
150 to 115200 bps
7 / 8 bits
None / Even / Odd parity
1 / 2 bit
IN/OUT
OUT
IN
OUT
IN
1
Open (not connected)
2
RS-232C communication line
3
RS-232C communication line
4
Connect to pin 6
5
6
Connect to pin 4
7
RS-232C communication line
8
RS-232C communication line
9
Open (not connected)
Voltage(V)
Mark
-5 to -15
-3 to -15
-5 to -15
-3 to -15
Note
Figure 10: RS-232C D-Sub9pin
F-100 SR
1st
Default setting
9600 bps
8 bits
None
1 bit
Space
+5 to +15
+3 to +15
+5 to +15
+3 to +15
1
6
5
9
Connector
14

Advertisement