NLV-5201 Specifications Manual

8 Interface Specification

The NLV-5201 uses these interfaces:
RS-232C
USB (COM/HID)
8.1

RS-232C Interface

This section describes RS-232C serial communications between the imager scanner and a host
computer. If the host COM port is not open, the imager scanner cannot send data and will emit
an error sound.
Note: With the RS-232C interface, the imager scanner can transfer images.
8.1.1
RS-232C Communication Settings
Base Communication Settings
Setting
Value
Baud rate
300 to 115200 bps
Data length
7 bits, 8 bits
Parity bits
None, Even, Odd
Stop bits
1 bit, 2 bits
8.1.2

Interface Signals

Signal names are based on signals transmitted from the imager scanner to the host.
Interface Signals
Name
Cable Color
VCC
Red
Trigger
Brown
OK
Yellow
NG
Orange
S-GND
Black
RTS
Gray
CTS
Blue
TxD
Green
RxD
White
Shield GND
(Black)
10
Default
9600 bps
8 bits
None
1 bit
Notes
Power-supply voltage 4.5 V to 5.5 V (Typ. 5 V)