Printed Contrast Signal (Pcs); Minimum Resolution; Barcode Width; Figure 5: Barcode Width - Opticon F-100 SR Specification Manual

Fixed position 1d linear imager scanner
Table of Contents

Advertisement

8.4

Printed Contrast Signal (PCS)

PCS 0.45 or higher
Conditions
MRD
Distance

Barcode width

Barcode
MRD = Minimum reflectance of white space – Maximum reflectance of black bar
Reflectance of white space – Reflectance of black bar.
PCS =
Note: Be sure to keep the optical window clean without dirt or scratches, or it may deteriorate the reading
performance.
8.5

Minimum Resolution

0.125mm (Code 39 specified in Section 8.1)
Conditions
Bar code
Distance
Angle
Curvature
8.6
Barcode Width
80 mm
Conditions
Barcode
Distance
Angle
Curvature
SPECIFICATIONS MANUAL
32% (
80% reflectivity of space and quiet zone)
35 mm from the front edge of the scanner
Maximum 60mm
Code 39. Resolution = 0.19mm / PCS 0.45, specified in Section 8.1.
Reflectance of white space
Above code specified in Section 8.1.
35±5 mm from the front edge of the scanner
α = 0°, β = + 15°, γ = 0°
R = ∞
Code 39. Resolution = 0.19mm / PCS 0.9, specified in Section 8.1.
35 mm from the front edge of the scanner
α = 0°, β = + 15°, γ = 0°
R = ∞
35

Figure 5: Barcode width

F-100 SR
[Unit: mm]
1st
11