CE
This section describes a summary of precautions when bringing into CE conformance the machinery formed by using the
vision sensor.
Note that the descriptive content is material created based on regulation requirements and standards obtained by Mitsubishi
Electric Corporation. However, machinery manufactured in accordance with this content is not necessarily guaranteed to
conform with the above commands.
Final judgment regarding CE conformance or the method of conformance must be the judgment of the machinery
manufacturer itself.
To meet the CE compliant conditions, implement the following items.
• Significant amount of noise on the power source may cause malfunction. Use a regulated DC power supply with an
isolating transformer for the power supply. Additionally, install a noise filter (SNR-10-223 by COSEL or an equivalent
product) between the vision sensor and the regulated DC power supply.
Precautions
Ground the FG terminal with the ground cable as short as possible (with the length of 30 cm or shorter).
• EMC application
Item
EMC applicable standard
2
Vision sensor
EN61131-2
Programmable controller product (Example: MELSEC iQ-R
series)
EN61131-2