6.10

ID with Alarm flag function

This function is implemented since the FW version 5.0.
It is possible so set an
relevant alarm is raised (and the alarm output is switched for preset time).
6.11

Antipassback function

This function is implemented since the FW version 5.0.
The Antipassback function is defined in two ways:
– user cannot repeatedly use his ID for defined time
Time APB
– user cannot repeatedly enter an area, where he is already present
Zone APB
The Antipassback function is used
schedule. The users with access always granted are not affected by the Antipassback
function.
The Antipassback flags for an
programming cards
access rights data are downloaded
Both Zone and Time Antipassback flags are written either immediately
after relevant
door is opened
6.11.1 Time Antipassback
The
Time Antipassback
the ID after passing at the reader module. If the users uses the ID at the address during the
timer for the ID is running, the Time APB alarm is raised. Following parameters affect the
Time APB function:
APB timer initial value
passing at the reader module. If a user uses the ID again before the timer elapses, Time
APB alarm is raised.
Open door after APB time alarm
performed after the Time APB alarm is raised.
Clear opposite APB flag
a reset of the APB timer flag at the opposite side (entry reader) of the module.
In case of using the operating mode Standard with Entry reader the time APB function is
evaluated at the entry reader only.
6.11.2 Zone Antipassback
The
Zone Antipassback
APB flag is set for the ID when passing at the reader module. If a user uses the ID again
when the Zone APB flag is set, the Zone APB alarm is raised. Following parameters affect
the Zone APB function:
Alarm – ID flag
for every
only for the
ID
can be
(offline solution).
All Antipassback flags
from the program.
(relevant input is disconnected).
is defined by the
– defines the Time APB flag (timer) value set to the ID after
– if the option is enabled, the Door open function is
– if the option is enabled, passing at the reader module causes
is defined by
enabling the option
Page 20
ID
stored in the module. When the ID is read,
users, whose access is driven by a
reset
by
inserting the ID again
are also
ABP timer initial value
for the relevant address. The Zone
with use of the
reset
whenever new
after an ID is
read, or
(in minutes), which is set to
time