Installation instructions ..................8 4 Wiring diagram ......................8 Simple connection of MREM 82 MTM-MF and MTM X1 or IP without POE..8 Simple connection of MREM 82 MTM-MF and MTM IP with POE ......9 Wiring diagram of MREM 82 in MTM panel integrated in system APS mini Plus 11 5 Setting parameters of the reader module ..............
, MIFARE DESFire and NFC tag technology, the reader is compatible with mobile phones equipped with NFC Pic. 1: MREM 82 MTM-MF ® technology and minimum OS Android 4.4 Kit Kat (or higher). Mobile ID application needs to be installed. The mobile phone can be used for identification instead of classic cards (card emulation mode).
Page 4
125 kHz product version overview Module features Catalogue Product designation Panel Surface System number ✓ MREM 81 MTM-EM APS mini plus Brushed aluminum 53481001 ✓ MREM 81 MTM-TF APS mini plus Brushed aluminum 53481000 ✓ Black zamak MREM 81 MTMVR-EM APS mini plus MTM VR 53481011...
3 Technical parameters 3.1 Technical features 8 ÷ 28 VDC Supply voltage Nominal 42 mA @ 12V, 23mA @ 24 V Input current Peak 124 mA @ 12V, 62mA @ 24 V Typical power 0,5 W Peak power 1,5 W ®...
You can download the application on Google Play for free. Pic. 3: Google Play and TF mobile ID 3.3 Mechanical design Pic. 4: MREM 82 MTM-MF Weight 122 g -25 ÷ 70 °C Operating temperature 5 ÷...
3.4 Cabling The cable consists twelve wires AWG 26. The wires are not dedicated for heavy loads, OUT1, OUT 2 and appropriate power supply and ground wires are designed to be connected to standard electromechanical mortise lock, door openers or magnets where the DC current does not exceed the load of 1A.
4.1 Simple connection of MREM 82 MTM-MF and MTM X1 or IP without POE One of the simplest wiring of MREM 82 MTM-MF and MTM panel together is to use OUTPUT 1 of MREM 82 MTM-MF to short-circuit the exit button input of the MTM panel.
4.2 Simple connection of MREM 82 MTM-MF and MTM IP with POE If there is a LAN switch with integrated POE, the MTM panel and MREM 82 MTM-MF can be both powered from POE. The estimation of power requirement should be calculated for example if there are more MTM modular modules used.
Page 10
Pic. 6: Utilization of POE power supply. Page 10...
5 Setting parameters of the reader module 5.1 Configurable parameters Parameter Possible range Default setting 0 255 s Door lock release time Door lock control setting Direct / reverse Direct Door lock relay function setting Standard / toggle / pulse Standard Permanent door lock release according to Never / Schedule index...
Detailed instructions for setting reader module parameters are described in the configuration program user’s guide available address Reader http://www.techfass.cz/files/m_aps_miniplus_reader_en.pdf. 6 Reader module functioning The reader module supports the following functions: • Standard “Door Open” function. • Door status monitoring. •...
By default, the blanking time is set to 6µs for the door lock output, and bit used for the alarm output. 6.3 Function permanent door lock release according to a time schedule When the function is set, the door lock is permanently released when relevant time schedule is valid.
6.4.2 Door Ajar alarm If the door stays open until the pre-defined Door ajar timeout expires – see Tab. 9, the “Door Ajar“ alarm is activated. 6.4.3 Antipassback alarm Antipassback alarm is raised when an ID is read during the Time APB counter is running or when the ID is blocked by a...
Page 16
6.6.1 Inserting cards into the reader’s memory Follow these steps for inserting cards into the reader module’s memory: Step 1 Step 2 Step 3 Read the programming card One by one, read the cards About seconds after for inserting: the reader goes which are to be granted inserting the last card the reader module goes back...
Page 17
6.6.3 Deleting cards „above or below“ If a user loses his ID medium, it is usually impossible to delete the ID from the memory with the procedure described in the previous chapter, since the medium is no longer available (with an exception of entering the code at the keypad). Following procedure can be used for deleting such ID.
Page 18
6.6.4 Deleting all cards from the reader’s memory Follow these steps for deleting all cards from the reader module’s memory: Step 1 Step 2 Step 3 Read the programming card Read the programming card The reader module goes for deleting: the reader goes for deleting 5 times in a row;...
• – Delete it Card 4 gets lost using the card 2, which is available, and using the procedure from chapter 6.6.3 – Read + (inserting) programming card, then 5x + (inserting) programming card again, then card 2, and finally + (inserting) programming card again.
• – user cannot repeatedly use his ID for defined time Time APB • – user cannot repeatedly enter an area, where he is already present Zone APB The Antipassback function is used only for the users, whose access is driven by a time schedule.
The disabling status changes and disabled actions are logged in the events archive. 6.11 Online authorization Since the FW version 5.11 Online authorization of ID can be used in APS mini Plus system. When the feature is used, the ID validity is resolved in connected PC. To be able to use this authorization mode, the reader module has to be equipped with a license.