6 Reader module functioning

The reader module supports the following functions:
Standard "Door Open" function.
Door status monitoring.
Exit-devices contact monitoring.
Alarm output activated / acoustic signalization activated when any alarm condition
occurs.
IDS control in the relevant operating mode using the WIO 22 relay module
The "Door Open" function can be activated in 3 different ways:
Reading a valid ID medium (card, key fob, etc. – for the standard reader module and
the reader module with a reason keypad), reading a valid ID medium and entering a
PIN code (for the reader module with a PIN keypad), or entering a valid code (reader
module with a code keypad).
Pressing the exit button (according to configuration).
Via communication line (program request).

6.1 "Door Open" function description

In case the
standard function of the door lock relay
beeper activated
outputs stay active until the door is opened or the preset door lock release time has elapsed
- see configuration table.
In case the
toggle function of the door lock relay
and the
beeper
The beeper stays active until the door is opened or the preset door lock release time has
elapsed - see configuration table. The door lock relay status remains unchanged until another
"Door Open" function is activated.
In case the
pulse function of the door lock relay
for the time defined by the
activated.
In case the standard function of the door lock relay is set, reading a valid card during door
lock release resets the door lock release time.

6.2 Function permanent door lock release according to a time schedule

When the function is set, the door lock is permanently released when relevant time schedule
is valid. Reading a valid ID is standardly announced via the communication line (in online
operating mode). The forced door alarm cannot be raised when the door lock is permanently
released.
The permanent door lock release function and the toggle function of the door lock relay
are mutually exclusive.
(when not disabled) when the "Door Open" function is activated. Both
(when not disabled) when the "Door Open" function is activated.
is
activated
Pulse width
is set, the door lock is
is set, the door lock relay status is
is set, the door lock relay status is switched
parameter (ms) after the Door Open function is
Page 10
released
and the
switched