5.2 Reader module parameters setting

Detailed instructions for setting reader module parameters are described in the
configuration
Reader
http://www.techfass.cz/files/m_aps_miniplus_reader_en.pdf.

6 Reader module functioning

The reader module supports the following functions:
Standard "Door Open" function.
Door status monitoring.
Exit-devices contact monitoring.
Acoustic signalization (and online) activated when any alarm condition occurs.
The "Door Open" function can be activated in 3 different ways:
Reading a valid ID (card, key fob...).
Pressing the exit button (according to configuration) – cannot be used in alarm
condition.
Via communication line (program request).

6.1 "Door Open" function description

In case the
standard function of the door lock relay
beeper activated
outputs stay active until the door is opened or the preset door lock release time has
elapsed - see configuration table.
In case the
toggle function of the door lock relay
switched
and the
activated. The beeper stays active until the door is opened or the preset door lock release
time has elapsed - see configuration table. The door lock relay status remains unchanged
until another "Door Open" function is activated.
In case the
pulse function of the door lock relay
for the time defined by the
activated.
In case the standard function of the door lock relay is set, reading a valid card during
door lock release resets the door lock release time.

6.2 Current limit of OUT 1 and OUT 2

There is a current limit protection on both outputs, 1 A. In case of capacitive load, the
current limit can be activated and disable the output. If there is a short current peak, it is
possible to turn on so called ''blanking time''. This function disables the current limit
protection for the period set in the software to handle this short current peak. After this
period the current protection get back on its limit 1 A.
program
(when not disabled) when the "Door Open" function is activated. Both
(when not disabled) when the "Door Open" function is
beeper
is
activated
Pulse width
user's
guide
available
is set, the door lock is
is set, the door lock relay status is
is set, the door lock relay status is switched
parameter (ms) after the Door Open function is