6 Reader module functioning

The reader module supports the following functions:
Standard "Door Open" function.
Door status monitoring.
Exit-devices contact monitoring.
Alarm output activated / acoustic signalization activated when any alarm condition
occurs.
The "Door Open" function can be activated in 3 different ways:
Reading a valid ID (card, key fob...).
Pressing the exit button (according to configuration) – cannot be used in alarm
condition.
Via communication line (program request).

6.1 "Door Open" function description

In case the
standard function of the door lock output
beeper activated
outputs stay active until the door is opened or the preset door lock release time has elapsed
- see configuration table.
In case the
toggle function of the door lock output
switched
and the
activated. The beeper stays active until the door is opened or the preset door lock release
time has elapsed - see configuration table. The door lock output status remains unchanged
until another "Door Open" function is activated.
In case the
pulse function of the door lock output
for the time defined by the
activated.
In case the standard function of the door lock output is set, reading a valid card during
door lock release resets the door lock release time.

6.2 Function permanent door lock release according to a time schedule

When the function is set, the door lock is permanently released when relevant time schedule
is valid. Reading a valid ID is standardly announced via the communication line (in online
operating mode). The forced door alarm cannot be raised when the door lock is permanently
released.
The permanent door lock release function and the toggle function of the door lock output
are mutually exclusive.
(when not disabled) when the "Door Open" function is activated. Both
(when not disabled) when the "Door Open" function is
beeper
is
activated
Pulse width
is set, the door lock is
is set, the door lock output status is
is set, the door lock output status is switched
parameter (ms) after the Door Open function is
Page 9
released
and the

Advertisement