5.2 Configurable parameters

Parameter
Enabling of emergency function
Address on a communication line
Internal reader configuration
Operating mode
All parameters are given by programming through the MCA 168 control module, see
http://www.techfass.cz/files/aps_400_config_en.pdf

5.3 Reader module parameters setting

Setting of all parameters of the reader module can be done only when the module is
connected to the system bus of MCA 168 controller. Detailed instructions for setting reader
module parameters are described in the
user's guide available at: http://www.techfass.cz/files/m_aps_400_network_reader_en.pdf.

6 Reader module functioning

6.1 Operating modes

The
NREM 76
reader modules are intended for online operating mode on APS 400 system
BUS
(APS
BUS). The activity of the modules is defined by the system controller; so the
modules are able to provide various functions not only controlling of the door.
In case of the communication line fails the modules can work in offline mode (when the
emergency function
function for last 750 valid cards registered before can be performed in this mode only.

6.2 Emergency "Door Open" function description

When the "Door Open" function is activated, the door lock is released and the beeper
activated until the door is open or 5 s preset door lock release time has elapsed.
All events triggered while the offline mode is in progress are saved neither in the
controller nor in the reader memory.
is enabled) - it concerns the exit readers mostly. The "Door Open"
Page 10
Possible range
YES / NO
1  64
Configurable
Standard / Wiegand Input /
Wiegand Output
Table 12: Configurable parameters
APS 400 Network Reader
Default setting
NO
1
Standard
Standard
configuration program